- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
12V电机调速器可逆
Wide Voltage Multi Reversible governor HXZF-1Connection Ports:A main power ports:VCC positive supply DC12-60V.GND Negative , if you want to reduce the external interference shielding box connected to terminals or here at the cathode connected to the power supplyM + motor positiveM- motor negativeSecond, the control port :5V: driver board internal 5V power supply, the output capacity of less than 100mA, with potentiometer mode is recommended only to use , do not drive other circuitsPWM: external PWM control signal input level range ,3-20V , 2mA current requirements ;ADJ: external 0-5V or 0-10V control signal inputGND: ground control signals , such as the shield shell is not allowed to pick pick here is also not allowed in this place other circuits connected GND,DOWN: control signal, the internal coupler control signal and GND effective turn ( optocoupler turns on, can also be used microcontroller , NPN switch control )UP: control signal, the internal coupler control signal and GND effective turn ( optocoupler turns on, can also be used microcontroller , NPN switch control )STOP: control signal, the internal coupler control signal and GND effective turn ( optocouplerturns on, can also be used microcontroller , NPN switch control )Third, the mode setting :1, M1 = short , M2 = open circuit mode 1 ; potentiometer voltage three-stage control + STOP allowed to runSTOP LOW can control the motor ,After the input voltage of 2.5V , the motor stops ; Usually this range 2.4-2.6 , for interference .2.5 gradually accelerated to 0V reverse rotation ,2.5-5V forward speed rotation ; That middle position potentiometer stops on both sides of adjustment on both sides of the motor speed .2, M1 = open , M2 = short circuit, Mode 2 ; potentiometer voltage + DOWN state control Reversible , STOP allowed to run( The default value for this speed mode )STOP low ( short circuit to GND on ) is enabled, the driver can control the motor voltage and DOWN signals ; high motor brake stops , the voltage
文档评论(0)