- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
Linux ha fence设备测试
另外,在配置RHCS5.3时,Fence设备只ping通还不行,还必须经过测试,我在网上找了一篇IPMI的文章,现粘贴如下:What is IPMI?Intelligent Platform Management Interface[edit]AdvantagesLow cost. Available on most recent server systems. [edit]DisadvantagesThere is no way to retain power to the IPMI BMC if power to the host is lost. If power is lost to the host, fencing will fail. This will delay cluster recovery. It is recommended to either have a second fencing device (external power switch) or a server with multiple power supplies when using IPMI over LAN for fencing. Some IPMI implementations share an ethernet interface with the host operating system. If this interface is the same one used for the cluster communication, a loss of connectivity to this port will cause a need for fencing but also cause fencing to fail, delaying cluster recovery. It is recommended that the ethernet interface the BMC uses be reserved exclusively for BMC use; that is, the host operating system should not use the BMCs NIC. [edit]PrerequisitesYou will need the OpenIPMI packages and the ipmitool utility in order to use this mini-howto. On Red Hat Enterprise Linux 5 and CentOS 5, the packages you need are: OpenIPMIOpenIPMI-toolsYou will also need some free IP addresses which you assign to IPMI devices. This mini-HOWTO is for machines which have not had IPMI-over-LAN set up before. [edit]Basic ConfigurationSee if you can start ipmi:[root@et-virt05 ~]# service ipmi startStarting ipmi drivers:? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ? [??OK??]If it fails (FAILED), go have a beer or something, because the rest of this howto will not help you. If it succeeds, you should see something like this (may differ by hardware) in dmesg output:ipmi message handler version 39.1IPMI System Interface driver.ipmi_si: Trying SMBIOS-specified kcs state machine at i/o address 0xca8, slave address 0x20, irq 0ipmi: Found new BMC (man_id: 0x0002a2,??prod_id: 0x0000, dev_id: 0x20)??IPMI kcs interface initializedipmi device interfaceOk! Moving, on...[edit]LAN/LAN+ Configurat
文档评论(0)