网站大量收购独家精品文档,联系QQ:2885784924

CTMRI在评价缺血性心脏病中的作用PPT.ppt

  1. 1、本文档共42页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
CTMRI在评价缺血性心脏病中的作用PPT

Example of evidence of neointimal proliferation but the stent is patent. The long axis views of the proximal LAD suggest that the stent appears patent but the metal around the stent does cause blurring artifact and attenuation. One of the advantages of CT is that you can see in the short axis. This shows the view from the short axis: You see areas of hyperattenuation which suggests soft tissue or neointimal proliferation. This is confirmed by the images by X ray angiography The bottom panel shows complete occlusion of the stent. From the long axis view, you can see there is hyperattenutation in the stent center which suggests occlusion. This is confirmed on the long axis view and complete stent occlusion. Results are promising but if there is a high suspicion of instent restenosis,need to do cath. OBJECTIVE. Dual-source CT has excellent temporal resolution and allows good visualization of coronary vessels without heart rate control. Our aim was to evaluate the diagnostic performance of dual-source CT in the evaluation of coronary stent patency to determine whether the good temporal resolution would improve visualization of stents. SUBJECTS AND METHODS. Thirty-five consecutively registered patients (10 women, 25 men; mean age, 65 years) with 48 stents were examined prospectively without heart rate controlling agents. Observers evaluating image quality and patency of the stents were blinded to the results of invasive coronary angiography. In-stent restenosis was defined as more than 50% narrowing of the lumen. RESULTS. All stents were considered assessable for diagnosis with dual-source CT. In 85% (41/48) of the stents, image quality was good. Only two patent stents were misidentified as being stenotic. All other stents with stenosis and occlusion were correctly diagnosed. The sensitivity, specificity, positive and negative predictive values, and accuracy of dual-source CT in the detection of in-stent restenosis and occlusion were 100%, 94%, 89%, 100%, and

文档评论(0)

djdjix + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档