- 1、本文档共8页,可阅读全部内容。
- 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
空气-水风机盘管系统关键问题分析
中文2700字附 录附录A 外文翻译Analysis on typical problems in air-water fan-coil unit systemAbstract This paper has made the simple introduction about the essential feature and suitable situation of air-water fan-coil unit system. It also has made the key elaboration to equipment choice and examination about this system. Simultaneously has analysised on typical problems of this system in details not only theoretically but also practically, and also presents recommended proposals.Keywords fan-coil unit fresh air handling unit water system examination system features and Applications0 Introduction With the improvement of peoples living standards, social developmen Exhibition, central air conditioning construction also more and more. Air - water fan Coil system because of its uniQue advantage in the air conditioning system in civil buildin Share is growing. How to regulate the air - water fan Design of fan coil system, the air conditioning reQuirements at the same time the Ji, also becomes more and more important.1 System Features and application of occasions The advantage of this system is to be independent of each air-conditioned room Regulation, without disturbing each other; and the introduction of fresh air but also good Guaranteed room hygiene reQuirements; space occupied by the pipeline system is also small. Air - the biggest flaw water fan coil system is Summer Operation Dehumidification capacity state system is small; winter humidity conditions can not enter Line control. So it is very suitable for office, hotel and other needs of the independent Regulation, and the humidity is not strictly reQuired for the place.2 fresh air state point determination Air-water fan coil unit system, with fresh air state point .Different will directly decide the fresh air handling units and fan coil capacity.Small. Generally speaking, after treatment of fresh air state point in four cases.One is the fresh air to the indoor temperature; the second is the fresh air handlingThe indoor enthalp
您可能关注的文档
- 社区远程图像监控系统解决方案.doc
- 祝酒辞《全》(免费).doc
- 神奇图片_保证你没见过.doc
- 硕士论文基于DSP的心电监护仪器关键技术研究.doc
- 离合器中型载重车膜片弹簧离合器设计.doc
- 离合器课程设计3.docx
- 离子渗氮对马氏体时效钢微观结构和性能的影响.docx
- 离心通风器的设计.doc
- 科创学院新闻发布系统开发与实现.doc
- 科学健身指导.ppt
- 19.2.2.2一次函数的图象与性质(分层练习)-2023-2024学年八年级数学下册同步精品课堂(人教版)原卷版.docx
- 19.2.2.4一次函数与实际问题(分层练习)-2023-2024学年八年级数学下册同步精品课堂(人教版)解析版.docx
- PVC在塑料改性中如何挑选润滑剂?.docx
- 热塑性动态硫化橡胶.docx
- 发泡聚丙烯材料是如何生产的?.docx
- PLA的3种改性方法、6种常用阻燃剂.docx
- 10.3 物体的浮沉条件及其应用(分层练习)-2023-2024学年八年级物理下册同步精品课堂(人教版)(原卷版)2.docx
- 10.3 物体的浮沉条件及其应用(分层练习)-2023-2024学年八年级物理下册同步精品课堂(人教版)(解析版).docx
- 10.3 物体的浮沉条件及其应用(分层练习)-2023-2024学年八年级物理下册同步精品课堂(人教版)(原卷版).docx
- 10.3 物体沉浮条件及应用(原卷版)(人教版).docx
文档评论(0)