机组通电前检查.PDF
PRL-5B-2 Operation instructions on Production line Electric operation
_____________________________________________________________________
Inspect the set before power connection
★ Connect the wires and cables that require on-site connection.
★ All connectors are well connected.
★ All the limit switches have been installed and the positions will not make the moving parts
under its control exceed the range.
★ The following items of the distribution box and the corresponding electric components should
be confirmed:
☆ All the connections of wires and cables are tightly fixed and there is no come-off.
☆ There is no short circuit between phases
☆ The ground insulation resistance of phases should meet the requirement.
☆ There is no cross-link between the voltages of different levels.
☆ All the components are reliably grounded.
☆ The set value of the thermal relay should be correct and in the work state.
After that, turn on the power: The connection should be conducted according to the sequence of up
level first and then lower level. Turn on one and confirm that there is nothing abnormal and then
the next, till all are in connection.
Read and set the parameters of frequency converter
☆ The method for reading out and setting the parameters of frequency converter:
After being connected, it displays the initial picture. ①Press PRGM/RESET key to enter the
programming state; ②Display the first parameter name PR.-00; ③Press ▼and ▲ to find
the name of the parameter you want to inspect and set; ④Press FUNC/DATA key and
display the current value of the parameter; ⑤You can change the value by pressing ▲and ▼;
⑥Press FUNC/DATA key and display -END- and in 2 seconds, it will automatically return
to step②; the value of the parameter is changed; ⑦ Press PRGM/RESET key to return to
文档评论(0)