基于弹塑性分析方法的超限高层混凝土结构抗震性能分析-seismic performance analysis of overrun high-rise concrete structures based on elastic-plastic analysis method.docxVIP

  • 3
  • 0
  • 约6.51万字
  • 约 97页
  • 2018-05-18 发布于上海
  • 举报

基于弹塑性分析方法的超限高层混凝土结构抗震性能分析-seismic performance analysis of overrun high-rise concrete structures based on elastic-plastic analysis method.docx

基于弹塑性分析方法的超限高层混凝土结构抗震性能分析-seismic performance analysis of overrun high-rise concrete structures based on elastic-plastic analysis method

Seismic PerformanceStudyofHigh-rise Concrete StructureBased on theElastic-plasticAnalysisMethodAbstractInrecentyears,variousnumberofhigh-riseconcretestructureinChina continuetoemerge,andthecurrentspecificationforthisstructureelasto-plastic seismicdesignandperformanceevaluationofnarrationistoosimplifiedandfuzzy, especiallyinmethodselection,indexselectionkeyproblemsurgenttobeperfect andunified.In orderto investigatetheproblem ofusingelastic-plasticanalysis methodtoevaluatetheseismicperformanceofanirregularultra-limitconcrete structuretallbuilding,thispapertakesZhongXiang internationalHotelwhich locatedintheChiZhoucityofAnHuiprovinceastheobjectofthestudy.Then,this paperchoosesthedynamicelastic-plastic time-historyanalysismethodand the staticpushoveranalysismethod,whichusethefiniteelementsoftwareEPDA/PUSH tostudyonseismicperformanceevaluationofelastic-plasticstageandanalysisthe relatedtothestructure.Duringtheprocessofevaluatingperformance,themethod selection,softwareselection,performanceevaluationparametersetting,dataerrors andotherrelatedaspectsareanalyzedanddiscussedwhichbasedonthetop displacement,maximuminter-storydisplacementangle,interlayerharmfuldrift angle,floorplastichingedistributionandotherkeyindexes.Themain achievementsaredescribedasfollows.Anirregularultra-limitconcretestructuretallbuildingshouldnotuse standardsimplifiedinelasticdisplacementcalculationmethod,priorityshouldbe giventothedynamicelastic-plastictime-historyanalysismethod.Ifusingthe pushoveranalysismethod,easytocausesomeomissions,suchastheneglectofthe upperfloorscarryingcapacityisinsufficient.ThesoftwareEPDA/PUSHhastheadvantagesofsavingtimemodeling, butthetreatmentalsohaveobviousflaws-imagedisplayeffectisnotgood,the dataprocessingworktedious.Thispapersuggests,iftheinterlayerdisplacementangleexceedsthecode limits,weshouldfurtherexaminethemaximuminterlayerharmfuldriftangle,the bestisensurethattheinterlayerharmfuldriftangleinmaximuminterlayerdrift angleisnotmorethan50%.Thispaperprovesthatthe18~20laye

您可能关注的文档

文档评论(0)

1亿VIP精品文档

相关文档