The x-ray imaging system - El Camino College:X射线成像系统- El Camino学院.ppt

The x-ray imaging system - El Camino College:X射线成像系统- El Camino学院.ppt

  1. 1、本文档共52页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
The x-ray imaging system - El Camino College:X射线成像系统- El Camino学院

X-ray tube current or Filament circuit # of e- is determined by the temperature of the filament. The hotter the filament the more e- Are their any limiting factors to thermionic emission? mA selection Filaments Operate at currents of 3 to 6 amperes (A) Question? What is directly proportional to the number of x-rays reaching the IR? Exposure Timers The timer circuit is separate from the other main circuits of the imaging system It is a mechanical or electronic device whose action is to “make” and “break” the high voltage across the x-ray tube This is done on the primary side of the high voltage transformer. mAs Timers Monitors the product of mA and exposure time Terminates the exposure when the desired mAs value is reached Located on the secondary side of the high-voltage transformer since actual tube current must be monitored mAs Timers Designed to proved the highest mA for the shortest exposure Modern X-ray machines have falling-load generator Automatically adjusts to the highest mA at the shortest exposure time possible AEC Control AEC measure the quantity of radiation reaching the IR Automatically terminates when the IR has received enough radiation for desired OD Two types are common Flat, parallel plate ionization chamber Located between the patient and the IR Made radiolucent Ionization w/in the chamber creates a charge; calibrated to produce a given OD on the IR Photomultiplier (Photodiode) detector assembly Located behind the IR Contains a fluorescent screen and a photomultiplier The photomultiplier detects the light from the fluorescent screen until the desired OD on the IR is reached terminating the exposure AEC’s Upon instillation must be calibrated by the service engineer Technologists selects the desired OD which then sets the mA kVp AEC’s A back up timer usually automatically set to prevent over exposure if the AEC fails Should be set to 1.5 times the expected exposure time Why? When the ionization chamber or photodio

文档评论(0)

138****7331 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档