发电机组热工对象自抗扰控制及其参数优化-动力工程及工程热物理专业论文.docxVIP

发电机组热工对象自抗扰控制及其参数优化-动力工程及工程热物理专业论文.docx

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
发电机组热工对象自抗扰控制及其参数优化-动力工程及工程热物理专业论文

working condition as well as excellent dynamic and static control performance when relative to traditional PID decoupling control. Malfunction of steam generator is the main cause of unexpected shutdowns and loss of capacity factor in nuclear power plants. Therefore, the ADRC scheme was presented for steam generator water level control system. The internal and external disturbances of the system were estimated and dynamic compensated by the extended state observer; meanwhile, the contradiction of the control system between rapidity and overshoot was alleviated through the nonlinear feedback regulation based on state error vector. However, ADRC parameters are numerous and without uniform adjustment specification, and are very difficult to be tuned by cut and try method with larger workload, it also difficult to popularization and application in engineering practice. The false water level make the nuclear steam generator water level difficult to identify, so, a kind of second-order diagonal recurrent neural network (SDRNN) identification method which has simple structure with fast and accurate identification ability was proposed, and the SDRNN is used to prompt track SG water level Jacobian information and dynamic identification the change rate of water level in order to real time optimization ADRC parameters. Besides, the simulation tests of the controller under different disturbances such as water level disturbance, steam disturbance, feed water disturbance and load change were carried out, the simulation results indicate that the SG water level control scheme which was based on SDRNN-ADRC can effectively inhibit the instantaneous false water level and also has a better quality of identification and control. Keywords:Active Disturbances Rejection Control, Firing Rate to Feed Water Ratio, Decoupling Control, Steam Generator Water Level, Identification and Optimization 目 录 中文摘要...........................................................................................

您可能关注的文档

文档评论(0)

peili2018 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档