- 1、本文档共63页,可阅读全部内容。
- 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
地源热泵冬季工况土壤温度变化特性研究-供热、供燃气、通风及空调工程专业论文
华
华 中 科 技 大 学 硕 士 学 位 论 文
II
II
Abstract
The GSHP (Ground Source Heat Pump system) is a new heat pump technology which grows up with the advent of the global environmental problems and energy crisis. The GSHP uses the energy which stored in the soil within 200m underground to serve for heating and air conditioning in buildings. It has good energy saving and environmental benefits, and gets increasingly wide attention and application in china recently.
This paper focus on the GSHP system in a 3-level office building in wuhan, the purpose of which is to study the soil temperature field changes under dynamic load. First by using the building energy consumption analysis software EnergyPlus to get the building’s max heating and cooling load. And then simulate the whole GSHP system according to the actual situation to get the hourly water temperature that enters the U-tube.
In order to provide advice and reference for the GSHP design and construction, this paper use Fluent to simulate the radius of 2.5m area to get the soil temperature field changes under two different boundary conditions during the heating period and the outage.
The results show that, during the winter condition, the outlet water temperature and the soil temperature changes are contrary to the heating load changes during the heating session, and the soil temperature decrease gradually from the center to distal. The soil temperature recovers fast under the constant wall temperature boundary condition, while keeps falling down under the adiabatic boundary condition as the ground heat exchanger absorbs heat from the soil continually. The soil temperature recovers much faster in the first five days after the units shut down, and then gradually slow later on. The distal soil temperature changes small under the constant wall temperature boundary condition, and the whole area temperature will rise to the wall temperature in a long term recovering. While the distal soil temperature keeps falling under the a
您可能关注的文档
- 地区电网无功优化的研究-电力系统及其自动化专业论文.docx
- 地区电网智能营销系统的研究和开发-电气工程专业论文.docx
- 地区电网电压无功优化控制研究-控制工程专业论文.docx
- 地区电网的事故控制及处理策略研究-电力系统及其自动化专业论文.docx
- 地区电网电压无功优化控制研究控制工程专业论文.docx
- 地区电网电压无功实时优化调度方案的研究-电力系统及其自动化专业论文.docx
- 地区电网继电保护整定计算系统的研究与应用-水利水电工程专业论文.docx
- 地区电网自动电压控制系统(AVC)在邢台电网中的应用研究-电气工程专业论文.docx
- 地区电网解列后安全稳定控制研究-电气工程专业论文.docx
- 地区电网调度管理信息系统研究-电气工程专业论文.docx
- 计量规程规范 JJF 2153-2024强脉冲光治疗仪校准规范.pdf
- 《JJF 2153-2024强脉冲光治疗仪校准规范》.pdf
- JJF 1176-2024(0~2 300) ℃钨铼热电偶校准规范.pdf
- 《JJF 1176-2024(0~2 300) ℃钨铼热电偶校准规范》.pdf
- 计量规程规范 JJF 1176-2024(0~2 300) ℃钨铼热电偶校准规范.pdf
- JJF 2154-2024亚低温治疗仪校准规范.pdf
- 计量规程规范 JJF 2154-2024亚低温治疗仪校准规范.pdf
- 《JJF 2154-2024亚低温治疗仪校准规范》.pdf
- JJF 2180-2024婴儿辐射保暖台校准规范.pdf
- 计量规程规范 JJF 2180-2024婴儿辐射保暖台校准规范.pdf
文档评论(0)