网站大量收购独家精品文档,联系QQ:2885784924

课件:心脏起搏器心电图.ppt

  1. 1、本文档共110页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
课件:心脏起搏器心电图.ppt

* Pacemaker 2:1 block is characterized by two sensed P waves per paced QRS complex. This pattern develops because every other P wave falls into PVARP. Starting on the left side of this ECG, the sequence begins with a sensed P wave. This P wave initiates a SAV, followed by a paced ventricular event. The next P wave falls into the PVARP, started by the ventricular pace, so no SAV is initiated. The following P wave is sensed outside of the PVARP, so a SAV is started. Again, no ventricular event occurs during the SAV, so the pacemaker paces in the ventricle. In this manner, a 2:1 block pattern is created. The rate at which the pacemaker will exhibit a 2:1 block pattern is determined by the SAV and the PVARP (or the TARP). Atrial rates with a P-P coupling interval shorter than the TARP will result in 2:1 block. To determine at what rate the pacemaker will go into 2:1 block, the TARP is simply converted from an interval to a rate. Therefore, the rate the pacemaker will go into 2:1 block is: 60,000/TARP. * * If the upper tracking rate interval is longer than the TARP, the pacemaker will exhibit Wenckebach behavior for some period of time before it goes into a 2:1 block pattern as the atrial rate increases. If the upper rate interval is shorter than the TARP, the pacemaker will exhibit 2:1 block behavior first and will never be able to achieve the upper tracking rate as the atrial rate increases. This situation is not as desirable as the situation in which there is a period of Wenckebach before 2:1 block because patients can tolerate the gradual ventricular rate drop of Wenckebach better than the precipitous ventricular rate drop caused by 2:1 block. * Welcome to Troubleshooting, a course module in CorePace. This module addresses the steps used in troubleshooting-defining the problem, identifying the cause, correcting the problem and verifying the solution. * CorePace Module 4: Troubleshooting The causes of undersensing, oversensing, noncapture, lack of output, and pseud

您可能关注的文档

文档评论(0)

iuad + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档