- 1、本文档共4页,可阅读全部内容。
- 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
Lesson 29 electricity distribution system
An a.c .distribution system is provided from the main switchboard which is itself supplied by the alternators .The voltage at the switchboard is usually 415 but on some large installations it may be as high as 3300. Power is supplied through circuit breakers to larger auxiliaries at the high voltage. Smaller equipment may be supplied via fuses or miniature circuit breaker. Lower voltage supplies used, for instance ,for lighting at 220 volts ,are supplied by step down transformers in the distribution network.
The distribution system will be three wires with insulated or earthed neutral. The insulated earth has largely been favored but earthed neutral systems have occasionally been installed. The insulated earth system can suffer from surges of high voltage as a result of switching or system faults which could damage machinery. Use of the earthed system could result in the loss of an essential service such as the steering gear as a result of an earth fault. An earth fault on the insulated system would not however break the supply and would be detected in the earth lamp display. Insulated systems have therefore been given preference since earth faults are a common occurrence on ships and a loss of supply in such situations cannot be accepted.
Equipment for a.c.systems is however smaller and lighter because of the higher voltage and therefore lower currents. Miniature circuit breaker are used for currents up to about 100 A and act as a fuse and circuit breaker. The device will open on overload and also in the event of a short circuit. Unlike a fuse ,the circuit can be quickly remade by simply closing the switch. A large version of this device is known as the moulded case circuit breaker and can handle currents in excess of 10000 A. Preferential tripping an earth fault indication will also be a part of the a.c.distribution system. These two items have been mentioned previously for d.c.distribution systems.
The generated
文档评论(0)