Lesson 29 electricity distribution system
An a.c .distribution system is provided from the main switchboard which is itself supplied by the alternators .The voltage at the switchboard is usually 415 but on some large installations it may be as high as 3300. Power is supplied through circuit breakers to larger auxiliaries at the high voltage. Smaller equipment may be supplied via fuses or miniature circuit breaker. Lower voltage supplies used, for instance ,for lighting at 220 volts ,are supplied by step down transformers in the distribution network.
The distribution system will be three wires with insulated or earthed neutral. The insulated earth has largely been favored but earthed neutral systems have occasionally been installed. The insulated earth system can suffer from surges of high voltage as a result of switching or system faults which could damage machinery. Use of the earthed system could result in the loss of an essential service such as the steering gear as a result of an earth fault. An earth fault on the insulated system would not however break the supply and would be detected in the earth lamp display. Insulated systems have therefore been given preference since earth faults are a common occurrence on ships and a loss of supply in such situations cannot be accepted.
Equipment for a.c.systems is however smaller and lighter because of the higher voltage and therefore lower currents. Miniature circuit breaker are used for currents up to about 100 A and act as a fuse and circuit breaker. The device will open on overload and also in the event of a short circuit. Unlike a fuse ,the circuit can be quickly remade by simply closing the switch. A large version of this device is known as the moulded case circuit breaker and can handle currents in excess of 10000 A. Preferential tripping an earth fault indication will also be a part of the a.c.distribution system. These two items have been mentioned previously for d.c.distribution systems.
The generated
您可能关注的文档
- 流程梳理培训.doc
- 流行病学在社区护理中的应用-社区护理学(全套完整课件)-课件.ppt
- 硫酸锰生产新工艺研究.doc
- 六边形垫片的复合模设计(有图纸).doc
- 六档变速器超详细毕业论文.doc
- 六年级备考会议发言 (共5篇).doc
- 六年级上册语文重点课文课内阅读题.doc
- 六年级英语下册unit2last weekend说课稿.docx
- 六一儿童节的两人搞笑短小品.doc
- 六一儿童节发言稿庆六一乡党委政府领导讲话稿.doc
- 分析let s单元56ago2卷纸zheng unit56.pdf
- 塑胶材料其它分类原料pa9t 12.pdf
- md16x16数字媒体切换器设备.pdf
- 者参考项目发起人学科类型单位序列承包商修订页代码顺序典型.pdf
- 届世界天然气大会阿姆斯特丹2006add10288.pdf
- 期测试记录表每周weekly g1g6 journeys tests level 6 lesson26.pdf
- modernize-whitepaper现代化您应用程序白皮书.pdf
- anybackup产品典型案例分析.pdf
- 约克金融工程课程tfeslide32.pdf
- 广州市妇女儿童医疗中心历份教学药历01tjy.pdf
文档评论(0)