I S O / E N 1 2 9 4 4
This standard, which is both a new International Standard and a European
Standard, has been given positive votes by both the International and European
committees and can now proceed to being a full published standard. It is unlikely
that this will be the case for all parts until mid 1998 at the earliest.
It should be noted, that because of the approval given by the European committee,
this standard will replace existing national standards such as BS5493 and DIN
55928.
The main problem I see at the moment is that it appears unlikely that the US based
specifying houses will use the specification, but will continue to use SSPC and
NACE guidelines.
ISO 12944 states that it is designed for use by engineers who have some technical
knowledge in the area of corrosion protection, as well as knowledge of other
relevant specifications.
Many will find the durability ranges to be extremely useful - this is the estimated time
to first major maintenance. This needs to be agreed between the interested parties
with reference to ISO 4628/1 to ISO 4628/5. It should always be realised that much
less effort is required to maintain a coating which has broken down to Ri2 than one
which has broken down to Ri3, for example.
The ‘durability’ ranges considered are:-
Low 2-5 Years
Medium 5-15 Years
High 15 Years
and are assuming the coating has reached a breakdown level of Ri3.
(It is emphasised that the durability range is not a guarantee time. It is purely
present to help the owner of the structure estimate sensible maintenance times.
The guarantee time is generally shorter than the durability range, and there is no
simple relationship between the two.)
MJM/19/07/97/GD Page No. 1
I S O / E N 1 2 9 4 4
SUMMARY SECTIONS
ISO 12944-2 Covers the corrosivity of various environments and how these can
be measured. Various anti-corrosive systems can then be
specified for these environments.
IS 19244-3 Deals with best practices in structural steel design from a corrosion
prevent