Bode 100 Application Note 直流模块电源环路稳定性分析
DC/DC Converter Stability Measurement
Strongly supported by
Smart Measurement Solutions
Table of Contents
1 Introduction 3
2 Measurement Setup 4
2.1 The Circuit under Test 4
2.2 Selecting the Injection Point 5
2.3 Connecting the Bode 100 6
2.4 Phase Margin and Gain Margin 8
3 Device Configuration 9
4 Measurement Results10
4.1 Calibration 10
4.2 Shaped Level 12
4.3 Injection Level 14
4.4 Supply Voltage Influence 15
4.5 Load Current Influence 15
5 Conclusion 16
DC/DC Converter Stability Measurement Page 2 of 17
Smart Measurement Solutions
1 Introduction
In this application note we show how to analyze the stability respectively the control loop behavior of a
step-down DC/DC converter.
To minimize the influence of supply voltage variations and load changes on the output voltage of a
DC/DC converter, a compensating controller is necessary. The quality of this control circuit
determines the stability and dynamic response of the entire DC/DC converter system. The following
pages show you how you can measure the loop response of such control systems using the Bode 100
vector network analyzer in combination with the B-WIT 100 wideband injection transformer.
For the characterization of the loop we measure the open loop gain by using the voltage injection
method. This method is commonly used to analyze the stability of voltage regulators such as switched
mode power supplies.
The following points are discussed in this document :
How to choose the correct injection point to measure the loop gain
Determining gain margin and phase margin from the frequency response
How do supply voltage and load current influence the systems dynamics
Using the shaped level feature of the Bode 100 to impr