出厂质量报告eh仪表发货说明书dti200.pdfVIP

  • 4
  • 0
  • 约3.56千字
  • 约 8页
  • 2021-01-27 发布于北京
  • 举报
Power supply 24 V DC (20...30 V DC) Power consumption 2.5 W Outputs • Current output 4...20 mA, active The measuring system can measure flow in both directions, i.e. bidirectionally. The current output is always positive. The relay responds to both flow directions. • Relay output Potential-free change-over contact 60 V AC/0.4 A 75 V DC/0.5 A Ambient temperature -20...60 °C Process temperature -20...120 °C (weld stub 1.4435 wi lamp ring) -20...100 °C (weld stub St.37 wi lamp ring and NBR gasket) Pressure 16 bar at 25 °C; 10 bar at 120 °C Full scale value 1...5 m/s (infinitely variable) Accuracy ±2% o.r. at measuring electrode with local calibration at flow velocities 1 m/s Reproducibility ±2% o.r. Conductivity ≥20 µS/cm Interference immunity acc. to CE EN 50081-1-2 und EN 50082-1-2 Protection type IP 66 / NEMA 4X / Type 4X Materials Sensor Sensor tip: PVDF, Viton O-ring Electrodes: 1.4435/316L Sensor sleeve: • 1.4435/316L with 1.4571/316Ti clamp ring for 1.4435/316L weld stub • 1.4435/316L wi lamp ring and NBR gasket for St.37