摘要:多热源环状 是一种新型的供热 形式。因其复杂的结构形式和工况变化,目前尚未建
立起较为完善的可及性分析的模型和求解方法,导致多热源环状 的设计改造、运行及调节存在
盲目性。本文建立了多热源环状 供热可及性分析模型,通过对该模型的求解能够对影响其供热
可及性的因素有一个定量的把握,为 的设计、改造及运行调节提供理论依据。
:多热源环状 ;供热可及性;定量判定
Study on Analysis Methods for Accessibility of District Heating
Loop-networks with Multi-heat Sources
XU Wenzhong, FENG Yonghua, ZHU Lanjun
(School of Civil Engineering, Henan Polytechnic University, Jiaozuo 454000, )
Abstract: Loop-networks with multi-heat sources is a new type of heating pipe networks. As this type of
networks have advantages over other types in aspects of accessibility and economy of heating. Thus, it has
been applied and developed gradually in domestic and abroad large-scale pipe networks. This paper aims to
study the analysis models for accessibility of loop-networks, then to assure the factors that influence
heating safety and to provide a theoretical basis for the regulation and technological transformation of the
pipe networks by solving the models though simulation.
Keywords: loop-networks with multi-heat sources; accessibility of heating; quantitative determination
1 引言
供热 的可及性,是在各热源及各热用户流量给定的情况下,通过对 的水
[1]
力工况进行分析模拟,判断 能否实现该流量分配 。具体地讲,就是在 结构、
各热源及各用户的流量为额定流量的一定的条件下,通过对 的水力工况的进行分
析,求出各用户或各热源的资用 ,判断该资用 能否满足各热源或各用户额定
流量的要求。因此, 的可及性状况是 的是固有属性,与 的水力失调是截
然不同的两个概念。对于可及的 ,从理论上讲,均能够通过合理的调节
您可能关注的文档
最近下载
- 1.2.2 比例 课件(共17张PPT)中职《机械制图》同步教学(人民邮电版)(内嵌音频+视频).pptx VIP
- 02S515排水检查井图集.pdf VIP
- 小学英语新人教版PEP四年级下册全册教案(2026春新版).doc
- 市政道路检测清单.docx VIP
- 贵安新区核心区城市综合交通规划文本.pdf VIP
- 2026年智慧树昆曲试题及答案.doc VIP
- 中考英语固定搭配专题训练50题含答案解析5篇.pdf VIP
- 教科版二年级科学下册教学计划.pdf VIP
- 2024年华为认证HCIE存储H13-629必备考试题库大全(含答案).docx VIP
- (统编版2026新教材)二年级语文下册全册教学设计.docx
原创力文档

文档评论(0)