Agilent Isolation of Basic Amines in the Presence of Acidic and Neutral Impurities from Human Plasma Using Silica-Based SCX (Strong Cation Exchange), Bond Elut SCX and SampliQ Si-SCX SPEs 说明书用户手册.PDF

Agilent Isolation of Basic Amines in the Presence of Acidic and Neutral Impurities from Human Plasma Using Silica-Based SCX (Strong Cation Exchange), Bond Elut SCX and SampliQ Si-SCX SPEs 说明书用户手册.PDF

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
Isolation of Basic Amines in the Presence of Acidic and Neutral Impurities from Human Plasma Using Silica-Based SCX SPEs Technical Overview Introduction A comparison study involving two silica-based, strong cation exchange (SCX) solid phase extraction (SPE) products was conducted, focusing on the recovery of two basic amines. In addition, one acid and two neutral impurities were spiked into human plasma to evaluate the selectivity for amines only. A five-component solution was spiked into human plasma containing 2% H PO . 3 4 The sample was then loaded onto a preconditioned SPE cartridge. The SPE cartridge was washed with 2% formic acid, then with methanol/acetonitrile (1:1) to remove any organic, nonbasic components. The basic components were then eluted with 5% NH OH/(methanol/acetonitrile (1:1)). 4 HPLC analysis of the SPE extracts used an Agilent ZORBAX Rapid Resolution Eclipse Plus C18 column with a gradient of 20 to 90% methanol/10 mM ammonium formate (pH 3.8). Both Agilent Bond Elut SCX and SampliQ Si-SCX showed comparable and consistent recoveries for the basic compounds used in this study. The extractions presented in this technical note suggest that the use of Bond Elut SCX (silica based SCX) gives a clean extract and high recovery of basic compounds, such as amines. Study Purpose and Methodology The purpose of the study was to evaluate performance differences between Agilent Bond Elut SCX and Agilent SampliQ Si-SCX, which are silica-based strong cation exchange SPE products, with respect to their retention of basic amines. The recov- eries of two basic components and the chromatographic profile of the eluents are evaluated to determine performance differences. Procainamide and chlorpromazine were chosen as representative bases. One acid and two neutral compounds were added to the base spiking solution as representa- tive acid and neutr

文档评论(0)

28974635 + 关注
实名认证
内容提供者

相近型号说明书可通用,具体看说明书包括型号

版权声明书
用户编号:5012033012000042

1亿VIP精品文档

相关文档