SPE-229654-MS

FieldEvaluationofNon-RadioactiveMultiphaseFlowMeters:Performance

Comparison,AccuracyandReliabilityAssessment

R.Almurayshid,H.Alshammari,E.Sadikhzada,andM.Alquraishi,SaudiAramco;N.Mehandi,Weatherford;H.

Gamal,WeatherfordSaudiArabia

Copyright2025,SocietyofPetroleumEngineersDOI10.2118/229654-MS

ThispaperwaspreparedforpresentationattheADIPECheldinAbuDhabi,UAE,3–6November2025.

ThispaperwasselectedforpresentationbyanSPEprogramcommitteefollowingreviewofinformationcontainedinanabstractsubmittedbytheauthor(s).Contents

ofthepaperhavenotbeenreviewedbytheSocietyofPetroleumEngineersandaresubjecttocorrectionbytheauthor(s).Thematerialdoesnotnecessarilyreflect

anypositionoftheSocietyofPetroleumEngineers,itsoicers,ormembers.Electronicreproduction,distribution,orstorageofanypartofthispaperwithoutthewritten

consentoftheSocietyofPetroleumEngineersisprohibited.Permissiontoreproduceinprintisrestrictedtoanabstractofnotmorethan300words;illustrationsmay

notbecopied.TheabstractmustcontainconspicuousacknowledgmentofSPEcopyright.

Abstract

Non-nuclearMPFMsofferanalternativetotraditionalnuclear-basedflowmeteringsystems,addressing

environmentalandregulatoryconcernswhilepotentiallymaintainingmeasurementaccuracyandreliability.

Theobjectiveofthisstudyistofieldtestanon-nuclearmultiphaseflowmeter(MPFM)andassessits

performanceunderchallengingoperatingconditions.

Anon-nuclearMPFMconsistingofSonar,NearInfra-red,andVenturiwasdeployedinoneofthe

stimulatedwellsduringflowbackoperationstoevaluateitscapabilitytomeasureflowratesofoil,water,and

gasphasesaccurately.TheMPFMdatawillbecomparedtoadownstreamconventionalseparatortoanalyze

themeasurementaccuracy,repeatability,andoperationalreliabilityunderthes