- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
沈阳百灵中央空调工程技术服务中心 电 网址: This is a part external elevation of an office building which we shall use as an example to demonstrate the calculation of building cooling and heating loads. This building has a ground floor and five other floors. The ground floor is smaller in area than the other floors and is shaded, from the sun, by the floor above. The five other floors are identical except for the top floor which would have heat gains and losses via the roof. The window area covers the majority of the building’s surface. Before any cooling or heating load calculations can be started the building drawings and specifications must be studied to determine the type of structural material used and the dimensions of the building. The ground floor has two cores containing lifts, lift lobbies, stairways and toilets. The lower core is incorporated into the building reception area. The building is orientated North, East, South, West. Each floor is an accumulation of modules each being 3.6m x 3.6m. The office area is the shaded portion. The chain dotted line is the perimeter of the floor above the ground floor. It overhangs East, South and North zones by a distance equivalent to the width of one module and will therefore provide shading to the ground floor. This is a cross section of the ground floor and a typical upper floor. The perimeter zone is 1.5 modules deep (5.4m). This is the distance at which partitions could be located. The circulation area is a place where a corridor would typically be located. The ceiling void is 600mm deep and would contain light fittings and air conditioning distribution equipment. The heat gains that effect the building can be divided as follows: Heat Gains From Outside: 1. Conduction Heat Gains: Due to the outside air being warmer than the inside air. When the outside air is cooler than the inside air heat will flow from the building causing a heat loss. During the morning or at night in summer there may well be a heat loss. 2. S
文档评论(0)