输油管道在投产和运行中可能出现的事故和处理.docVIP

输油管道在投产和运行中可能出现的事故和处理.doc

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
输油管道在投产和运行中可能出现的事故和处理.doc

输油管道在投产和运行中可能出现的事故和处理 18.1 Possible Accident Types of the Main Pump and Treatment Main kinds of failures with response procedures which may happen during commissioning are listed. 18.1.1 Mechanical Seal Leakage of Pump Two grades of protection are designed against seal leakage, HIGH protection and HIGH shutdown. In case that the leakage surpasses the HIGH protection value, the standby pump will be started, and the running pump must be shutdown immediately after the standby pump is started. In case that the leakage surpasses the HIGH limit, the pump shall be shut down promptly, protect the pump Units, start the standby pump at the same time. 18.1.2 The Low Pressure Protection Reaches the Alarming Value at the Inlet Valve Check the differential pressure at the strainer and the pressure from the upstream station. In case that the strainer is blocked, switch the strainer clean the blocked strainer immediately. In case that it is caused by the pressure from the upstream station, inform the upstream station to raise discharge pressure. If the pressure cannot meet the requirement of the pump, shut down the pump, and restart the pump when the pressure meet the requirement of the pump. 18.1.3 Unexpected Power Failure of Pump and Motor Start the standby pump units immediately. 18.1.4 The Temperature of the Main Pump Bearing and Casing Surpasses the Alarming Value In case that the temperature of the pump bearing or the pump casing surpasses the over temperature alarming value, start the standby pump units immediately, then shut down the malfunctioned pump. Check the malfunctioned pump and clear the fault. 18.1.5 The Temperature of Pump Bearing and Casing Surpasses the Protection Value Shut down the pump immediately to protect the pump units, start the standby pump units at the same time. 18.1.6 The Pump Bearing Vibrates too seriously There are two grades of protection to the pump unit’s vibration, over high protection and over finite protection. In case that the main pump vibr

文档评论(0)

docindoc + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档