- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
15.1 IntroductionFig.15-1 AC contactor forpump application15.2 Alternating-Current Contactor15.2.1 Alternating-Current Magnets15.2.2 Shading Coils15.2.3 Alternating-Current Coils15.2.4 Inrush Currents15.2.5 Remote Control15.2.6 Oil-immersed Contactors15.2.7 Control-voltage Transformer15.2.1 Alternating-Current MagnetsThe principal difference between AC contactors and DC contactors is in the design of the operating magnet. With the DC contactor, any heating of the iron frame arises from copper loss in the coil. With the AC contactor, heating of the frame comes from iron loss in the frame itself. The resistance of the coil is relatively low, and the copper loss is small. In order to reduce the iron losses, AC contactor magnets are made of thin laminations bolted together. 15.2.2 Shading CoilsFig.15-2 Operation of a shading coil15.2.3 Alternating-Current CoilsDC contactor coils have a large number of turns and a high ohmic resistance. The current through them is limited by the resistance. In AC coils, the current through the coil is limited by the impedance of the circuit, and the reactance has a greater effect than the resistance. Consequently, the resistance of an AC contactor coil is low, and the number of turns is relatively small. It is possible, therefore, to use heavier wire for these coils, which is fortunate for several reasons. With a relatively small number of turns there is a higher voltage drop per turn. Also, the AC coils are subject to continuous vibration caused by the reversal of the flux.15.2.4 Inrush CurrentsWith a DC magnet, the current in the coil is the same whether the contactor is opened or closed. However, with an AC magnet, the current in the coil is largely determined by the reactance of the circuit, which is lower when the contactor is open, because of the air gap in the magnetic circuit. Therefore, there will be a high inrush of current through the coil when the contactor is first connected to the supply line. 15.2.5 Remote ControlFig.15-3
您可能关注的文档
- 电气防火技术 教学课件 作者 高庆敏 第3章.ppt
- 电气防火技术 教学课件 作者 高庆敏 第5章(1).ppt
- 电气防火技术 教学课件 作者 高庆敏 第7章(2).ppt
- 电气防火技术 教学课件 作者 高庆敏 第8章_接地_接零安全与防火.ppt
- 电气防火技术 教学课件 作者 高庆敏 第11章_静电危害及其防护.ppt
- 电气防火技术 教学课件 作者 高庆敏 第九章.ppt
- 电气防火技术 教学课件 作者 高庆敏 第六章.ppt
- 电气防火技术 教学课件 作者 高庆敏 第十章 (1).ppt
- 电气防火技术 教学课件 作者 高庆敏 第四章.ppt
- 电气防火技术 教学课件 作者 高庆敏 封面.ppt
- 电气工程与自动化专业英语 教学课件 作者 王伟 16.pptx
- 电气工程与自动化专业英语 教学课件 作者 王伟 17.pptx
- 电气工程与自动化专业英语 教学课件 作者 王伟 18.pptx
- 电气工程与自动化专业英语 教学课件 作者 王伟 19.pptx
- 电气工程与自动化专业英语 教学课件 作者 王伟 20.pptx
- 电气工程与自动化专业英语 教学课件 作者 王伟 目录.pptx
- 电气工程与自动化专业英语 教学课件 作者 王伟v Chapter01电子课件.ppt
- 电气工程与自动化专业英语 教学课件 作者 王伟v Chapter02电子课件.ppt
- 电气工程与自动化专业英语 教学课件 作者 王伟v Chapter03电子课件.ppt
- 电气工程与自动化专业英语 教学课件 作者 王伟v Chapter04电子课件.ppt
原创力文档


文档评论(0)