TOFD超声波衍射时差法培训教程.pptVIP

  1. 1、本文档共52页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  5. 5、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  6. 6、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  7. 7、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  8. 8、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
TOFD超声波衍射时差法培训教程.ppt

* * * * * * * In practice however, the maximum error that will ocur on the absolute depth measurement will be limited. Due to the beam spread limitations of the probe the examined zone is limited and the maximum error in this zone will never be higher than about 10 %. The defect height estimation on the other hand will still be accurate since the height is calculated on the basis of two depth measurements.The absolute errors on the depth measurement are almost canceled by this process. A problem can arise for small defects situated at the back-wall. Due to the explained phenomenon they can appear deeper then they really are and thus become lost in the back-wall signal. This is one of the major problems of longitudinal scans and explains the need for tranverse scans, which will be explained later on. But, since the defect is initially not detected, the complete weld should be scanned transversally. And this annulates of course one of the major advantages of the TOFD technique, which is a high inspection speed. However, we will see later that a combination of the TOFD technique with the standard pulse-echo technique can efficiently resolve this, and other shortcommings of TOFD. * For the parallel scan, which is across the weld section, the path to the defect tip varies with the probe position because of the changing of the path lengths. This variation generates an inverted parabola curve which is typical for TOFD parallel scans. The path to the defect reduces to a minimum when the probes are positioned symmetrically over the defect. This allows for an accurate measure of the defect’s depth as discussed earlier. The parallel scan allows also to determine the lateral position of the defect. The minimum wave path indicates the place were both probes are symmetrical positioned over the defect. At this location the defect lies thus straight in the middle of both probes. For this purpose the software enables the drawing of locus curves that will be shown during the

文档评论(0)

文档精品 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:6203200221000001

1亿VIP精品文档

相关文档