Chapter 10Control Loop Troubleshooting.PPT

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
Chapter 10Control Loop Troubleshooting.PPT

Chapter 10 Control Loop Troubleshooting Overall Course Objectives Develop the skills necessary to function as an industrial process control engineer. Skills Tuning loops Control loop design Control loop troubleshooting Command of the terminology Fundamental understanding Process dynamics Feedback control Objectives for Control Loop Troubleshooting Be able to implement an overall troubleshooting methodology Be able to determine whether or not the actuator, process, sensor, and controller are functioning properly. Recall the major failure modes for each of the elements of a control loop. Troubleshooting Loops in the CPI Control Diagram of a Typical Control Loop Components and Signals of a Typical Control Loop What is Control Loop Troubleshooting? Control loop is suspected of not functioning properly. Poor overall control performance Erratic behavior Control loop was removed from service. Identify the source of the problem. Correct the problem. Retune the controller and monitor. Overall Approach to Troubleshooting Control Loops Check subsystem separately. Actuator system Controller Sensor Process Then check performance of the entire control loop What’s been changed lately? Checking the Actuator System Apply block sine wave input changes to the setpoint for the flow controller. Determine the deadband of the flow control loop from a block sine wave test. Also, estimate the time constant for the flow control loop from the block sine wave test. If the time constant is less than 2 seconds and the deadband is less than 0.5%, there is no need to evaluate the actuator system further Block Sine Wave Test Common Problems with the Actuator System Excessive valve deadband Improperly sized control valve Valve packing is tightened too much Improperly tuned valve positioner Check the Sensor System Evaluate the repeatability of the sensor during steady-state operation. Evaluate the sensor dynamics. This may require an independent measurement of the controlled variable. Or check the

文档评论(0)

gshbzl + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档