《HP SAS技术与架构4th》.pdf
Serial Attached SCSI technologies and architectures
Technology brief, 4th edition
Introduction 2
SAS devices 2
Initiators 2
Expanders 3
Targets 3
SAS protocol 3
Active cables 3
Storage power management 4
Differential signaling 4
SAS/SATA interoperability 5
SAS topologies 5
Internal 6
External 7
Multi-node clusters 8
Dual-path and dual-domain architectures 8
Dual-path with cascaded JBODs 8
Dual-domain SAS 9
Zoning 12
Zone management 13
Zoning advantages in an HP environment 14
Zoning example 15
Cabling and connectors technology 16
SAS drive performance 18
Conclusion 18
Appendix: SAS terminology 20
For more information 21
Introduction
Serial Attached SCSI (SAS) has become the de facto hard disk drive (HDD) standard for mission-
critical applications. This paper describes SAS devices, the SAS protocol, possible SAS topologies,
zoning, and interoperability with SATA devices and connectors. The Appendix defines technical terms
used in this paper.
SAS devices
There are three types of SAS devices: initiators, targets, and expanders. Initiator devices include host
bus adaptors (HBAs) and controllers. The initiator attaches to one or more targets, forming a SAS
domain. Target devices include SAS hard disk drives (HDDs) or solid state drives (SSDs), SATA HDDs
or SSDs, and SAS tape drives. Using expanders (low-cost, high-speed switches), you can increase the
number of targets attached to an initiator to create a larger SAS domain (Figure 1).
Figure 1: Example of SAS and SATA devices in a single domain
Initiators
SAS initiators have multiple ports for connecting to internal and external targets. Each initiator port
can have a single physical link (a narrow port) or two, four, or eight physical links (a wide port). You
can connect SAS initiator ports to separate domains for fail-over redundancy.
您可能关注的文档
- 《gl_vi-5-1_e》.pdf
- 《GMAT 2016 VERBAL SC新题》.pdf
- 《GMAT 2016版OG Reading Comprehension新题》.pdf
- 《GMAT Test Code 14 - finalized proofed》.pdf
- 《GMAT Test》.pdf
- 《gmat-math》.pdf
- 《GMATPrep 二零一六 语法笔记》.pdf
- 《GMAT_bulletin_二零一六_WEB021011》.pdf
- 《GMAT_GRE_LSAT_READING大全》.pdf
- 《GMAT_Strategy_V1.0》.pdf
- 灯光系统施工方案.docx
- 舞蹈技巧对学生身体协调能力的影响研究教学研究课题报告.docx
- 基于社区老年生活圈的开封龙亭区“体医养”公共服务设施配置与优化.docx
- 基于供需平衡的城市公共服务水平与人口集聚空间错位研究.docx
- 2025-2030年(全新版)中国缠绕膜行业规模分析及投资前景规划研究报告.docx
- 计及风光不确定性和需求响应的多能互补系统优化调度.docx
- 高中生英语读后续写中词块使用现状的调查研究.docx
- 适用于窄幅喷施的多旋翼植保无人机研制与试验.docx
- 高中历史与历史文化遗产保护研究教学研究课题报告[001].docx
- 初中美术课堂中素描训练对学生绘画技巧的提升研究教学研究课题报告.docx
文档评论(0)