Abstract
Full digital 400Hz single phase inverter with repetitive control algorithm proves poor in
dynamic characteristic In this paper,three methods are employed to improve its dynamic
characteristicwhich include resonant linkhalf period repetitive controland dual loop
control.
Based on the state-space averaging and linearization technique, the continuous and
discrete models of single-phase inverter are established with the load current treated as a
disturbance. To precisely determine the damping ratio of a no-load PWM inverter, an
experimental approach based on measuring the magnitude-frequency characteristic of the
inverter is proposed. Resonant link infulence to dynamic characteristic is analysed by
MATLAB. The emulational results show that resonant link does good to load disturbance
suppressing by reducing output impedance, but it does harm to instantaneous disturbance
suppressing.
A comprehensive theoretic analyze is carried out on repetitive control system. System
stability, error convergence and steady-state error are discussed. A geographic explanation is
presented for better understanding of the stability condition. The design of “plug-in”
repetitive control system is discussed in detail, and a improved scheme is presented here.
Based on the specialty that inverter has much less even harmonious than odd, half period
repetitive control is proposed.This novel repetitive control can reduce half dynamic
responding time ,which proved by emulational and experimental results.
State observer is used to compensate one-step-delay control .A dual-loop control
method