第27 卷 第18 期 中 国 电 机 工 程 学 报 Vol.27 No.18 Jun. 2007
2007 年6 月 Proceedings of the CSEE ©2007 Chin.Soc.for Elec.Eng.
0258-8013 (2007) 18-0083-06 TM561 A 470 40
文章编号: 中图分类号: 文献标识码: 学科分类号: ⋅
126kV 真空灭弧室1/2 线圈纵磁触头
三维磁场仿真
郝建成,杨嘉祥,王新掌,上官霞南
(哈尔滨理工大学电气与电子工程学院,黑龙江省 哈尔滨市 150040)
Simulation of 3-D Magnetic Filed in Two Segments Coil Axial Magnetic Field Contact of
126kV Vacuum Interrupter
HAO Jian-cheng, YANG Jia-xiang,WANG Xin-zhang, SHANGGUAN Xia-nan
(Electrical & Electronic Engineering College, Harbin University of Science and Technology, Harbin 150040,
Heilongjiang Province, China)
ABSTRACT: 3-D electrode model of two segments coil axial 关键词:真空灭弧室;1/2 线圈纵磁触头;三维静磁场;三
magnetic field(AMF) contact of 126kV vacuum interrupter was 维涡流场;仿真;电极结构
built up, and the 3-D magetostatic field and eddy current field 0 引言
for finite element model in case of discharge were simulated by
the 3-D finite element meshod. The results show that 真空断路器是目前中压领域应用广泛,技术性
deformation of the AMF on the slots is caused and the AMF 能优越的一种断路器[1-5] ,随着真空断路器制造技
distribution on mid-gap plane of contct is like a flat-roofed tent 术和理论研究水平的不断提高,以及人们对大气
under magetostatic field. The AMF distributions on the plane of 环境质量的重视,高电压、大容量真空断路器的
contact plate and mid-gap plane under eddy current field are
开发和研制已引起世界范围的广泛关注[1] 。真空断
similar with distributions under magetostatic field when current
is peak. There are a peak and six secondary peaks of AMF on 路器开断大电流的方式有 2 种:一种是在真空电
the pla
您可能关注的文档
最近下载
- 新版五年级下册海西家园教案.doc VIP
- 保险公司财务管理-复旦大学精品课程.PDF VIP
- 机动车驾驶人身体条件证明完整版_3616.doc VIP
- 课件:药物化学绪论.ppt VIP
- 第22课 健康生活新设备 课件 2025-2026学年人教版初中信息科技八年级全一册.pptx VIP
- (高清版)DB41∕T 2511-2023 怀山药零余子种栽繁育技术规程.pdf VIP
- 2016年江苏南京中考《数学》试卷+答案+解析.pdf
- word及Excel基础知识培训.ppt VIP
- 第四章 part1中华人民共和国教师法(课件)2024年《学前教育政策法规》同步教学(高教版).pptx VIP
- 大学毕业设计-小型播种机的设计 说明书.doc VIP
原创力文档

文档评论(0)