励磁电压365V;励磁电流2642A
一 、一次设备参数
1.#1发电机:QFSN-300-2-20型;Pe=300MW; Se=353MVA;Qe=186Mvar
Ue=20KV;Ie=10190A ;COSф=0.85;
Xd=16.8%/15.5%(非饱和/饱和) Xd′=22.7%/20%(非饱和/饱和);
Xd=186.1%; X2=16.7%/15.3%(非饱和/饱和)
2.#1主变:SFP10-370000/220GW Se=370MWA;Ue=242-3+12.5%/20KV; Ud=13.91%
882.7/1068A YN,d11
3.#1高厂变:SFF9-40000/20 Se=40000/25000-25000KVA; Ue=20+×2.5%/6.3-6.3KV
Ie=1154.7/2291-2291A