IV.2 Classification of Hazardous Zones
The hazardous zone resulting from a continuous source will be a greater hazard than the zone resulting from a primary source, because the probability is higher than it will contain a flammable mixture. To show this, hazardous zones are classified according to the type of source of flammable vapour or gas:
the hazardous zone resulting from a continuous source is normally classified as Zone?0
the hazardous zone resulting from a primary source is normally classified as Zone?1
the hazardous zone resulting from a secondary source is normally classified as Zone?2.
The parts of the facility which are not classified as hazardous zones can be designated non-hazardous but may still contain a flammable mixture under calamity conditions.
Hazardous zone classification depends on the grade of release and the ventilation available as shown in Table IV.1:
Table IV.1 Hazardous zone classification and impact of ventilation
Grades of release Open air situation adequately ventilated spaces with unrestricted air movement, i.e. at least 12 changes per hour Restricted ventilation, e.g. inside modules with ventilation stopped or less than 12 changes per hour No ventilation, e.g. inside tank Continuous Zone 0 Zone 0 Zone 0 Primary Zone 1 Zone 1 Zone 0 Secondary Zone 2 Zone 1 Zone 0 For land rigs, the open air situation is the norm, with restricted ventilation only present where the drill floor is shrouded, or inside the free space of active mud tanks, ditches and well cellar areas. There should be no Zone?0 areas on any drilling rig installation. Outside Zone?0, 1 or 2 the worksite is non-hazardous.
IV.3 Hazardous Zone Dimensions
According to the IP Code (1990) for Drilling and Workover Installations (where diagrams are provided), the Zone 2 hazardous zones around the rig equipment extend to:
1. A cylinder 7.5 m around the bell nipple extending 9?m below the wellhead deck (offshore) or to ground level. The upper extent of the Zone
您可能关注的文档
最近下载
- 小学生助人为乐PPT帮助他人快乐自己主题班会演讲ppt.pptx
- 3104112《心理健康与职业生涯学习指导》(答案).pdf VIP
- 企业文化与商业伦理(东北大)中国大学MOOC慕课 客观题答案.docx
- TCHSA-013-2023-牙周病患者正畸治疗指南.pdf VIP
- 云米互联网洗衣机(10KG)-产品说明书.pdf
- 小学语文主题式大单元整体教学研究课题报告(立项) .pdf
- 六年级下册道德与法治第4课《地球—我们的家园》第一课时 教案教学设计.doc
- 《心理健康》大学主题班会.ppt VIP
- IBM-长安汽车基于产品为主线的组织及管理体系诊断项目_福特案例研究-2016.pptx VIP
- 2023北京海淀三年级(上)期末语文试卷含答案.docx
文档评论(0)