recirculation_inlet recirculation_ioutet Q: I have created a 2D geometry of a room (3m x 5m) and supply air duct is connected at the top. I would like to find out flow structure around the discharge area. 我创建了一个二维几何房间,送风管道连接顶部。我想找出绕流排放区的结构。 Computational domain : Part of incoming duct part of room (0.6m x 0.8m )near to outlet. 计算域:进口管道部分及靠近出口的房间部分。 Selected boundary condition as follows: 选定的边界条件如下: Inlet to duct进口管道: pressure inlet 10Pa with 2 % intensity Top horizontal ceiling顶部的水平天花板: wall left side wall : wall Right side bottom both with in same pressure condition. Right side (0.8m from left wall) is set as: Pressure outlet Bottom (0.6 meter from ceiling) is set as pressure outlet Gauge pressure (总压) at the outlet boundaries (both vertical horizontal垂直及水平) is set to 0 as it is atmospheric pressure. For the above simulation, Fluent results does not show correct flow patterns. During the iteration, reverse flow also occurred. 回流 Do you think the problem may be due to 2 pressure outlet boundaries (Right side bottom)? 你认为问题可能出在2个压力出口边界(右侧及底部)? I extend the domain from left towards right. but still problem remain same as still need to define boundary. 我自左向右。但仍保持相同的问题仍然需要定义的边界。 I also extend the domain towards down wards (from ceiling to floor side), but problem remain same. 我还从天花板到地面侧延伸计算域,但问题仍然相同。 It is also not possible to extend domain as much as possible as file size become very large. Could you please let me know how to run this 2D model using Fluent with limited domain size (may be 1m x 1m). A: 1. Please increase the domain size to include complete room. If mesh count is a concern, you may want to use coarser mesh in the area of low gradients. 2. The 10 Pa pressure drop may not be enough for big room. Run the simulation with velocity inlet boundary condition with expected flow rate first. This will give you an indication of expected pressure drop in the domain. Q: Need your advice on following: A circulating fan duct heater is mounted(安装)

文档评论(0)

cxiongxchunj + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档