example f e d o o p potentialto emit evaluation(例子f e d o o p potentialto排放评估).doc

example f e d o o p potentialto emit evaluation(例子f e d o o p potentialto排放评估).doc

  1. 1、本文档共5页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
example f e d o o p potentialto emit evaluation(例子f e d o o p potentialto排放评估)

PTE Evaluation Scope: Construction/Modification/Plantwide Equipment: New 4k Wet Scrubber, make Integrated Environmental Services, Inc, model 4KV Existing Nebraska Boiler #4, 90 MMBtu/hr, Nat Gas, #2 fuel oil, or animal fat Existing Boiler #5, 63 MMBtu/hr, Nat Gas, #2 fuel oil, or animal fat Existing Dupps Cooker (E14) Existing Hair Hydrolyzer (E11) Existing 40k Scrubber Existing Two Condensers The company is installing a new 4,000 acfm Wet Scrubber and then routing the vapors to either Boiler #4 or Boiler #5 with the existing 40k scrubber being a backup control device for E14 Dupps Cooker and E11 Hair Hydrolyzer). There will be a dedicated condenser for each emission point before either option. Assumptions: PM = PM10 = PM2.5 for all equipment Dupps Cooker maximum production = 50,000 lb/hr (from previous PTE, this application only claims 25,000 lb/hr) PM loss = 0.10% Hair Hydrolyzer maximum production = 4,000 lb/hr PM loss = 0.05% There are no TACs PM outlet of the condensers and venturi scrubber = 2.7 lb/hr (Stack Test dated Nov 20, 2010) includes the addition of other emission points VOC outlet of the condensers and venturi scrubber = 6.377 lb/hr (Stack Test dated Nov 20, 2010) includes the addition of other emission points 40k Scrubber PM eff = 65.7% 40k Scrubber VOC eff = 72% 75k Scrubber PM eff = 87.5% 75k Scrubber VOC eff = 80% Assumed Venturi Scrubber eff = 75% for both VOC and PM Assumed Condensers (4) eff = 75% for VOC only Assume new 4k scrubber eff = 75% for both VOC and PM Assume Boilers eff = 99% for VOC only Calculations: Assuming at maximum all the PM and VOC comes from E11 and E14 Assuming 90% of the PM and VOC comes from the Dupps Cooker Dupps Cooker (E14) ((2.7 lbPM/hr)/(1 – 0.75))*0.90 = 9.72 lb/hr PM uncontrolled PM emission limit = 3.59P0.62 = 3.59(25)0.62 = 26.41 lb/hr ((2.7 lbPM/hr)/(1 – 0.75))*0.90*(8760 hr/yr)*(ton/2000 lb) = 42.57 PM tpy uncontrolled ((6.377 lbVOC/hr)/((1 – 0.75)*(1 – 0.75))*0.90*(8760 hr/yr)

您可能关注的文档

文档评论(0)

bgl001 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档