PART PROBE INSTALLATION: Disassemble the MP700 probe body, set the appropriate dipswitches within the body per the Hurco drawing. The switches as a default from Renishaw are not to Hurco standards. Refer to the supplied MP700 Renishaw manual for assembly instructions and location of switches. Switch settings: SW1-1=off, SW1-2=off, SW1-3=on, SW1-4=off. Switch settings: SW2-1=on, SW2-2=off, SW2-3=off, SW2-4=on. Insert the MP700 probe assembly into the spindle. Indicate the Ruby stylus to obtain a maximum run out of .0002”. Adjust the 4 grub screws in the alignment plate to achieve run out. Ref