德尔格Evita4呼吸机故障代码

2.1 Error code 02 Safety Software The service codes 02.00.. to 02.22.. are recognised on the CPU 68332 PCB; they correspond to 02.40.. to 02.62.. as recognised on the Pneumatic Controller PCB. Fault Item Cause/Remedy 02.00.001 si0_Err, New start, cause incorrect, reset Monitoring of cold/warm start storage in RAM on CPU 68332 PCB. Cause: Software error on CPU 68332 PCB 02.00.002 si0_Err, Fast data chksum error, reset Data packets between CPU 68332 PCB and Pneumatic Controller PCB cannot be transferred in full. CPU 68332 PCB or Pneumatic Controller PCB defective. 02.00.003 si0_Err, Safety software of partner CPU not started, reset After starting, it was not possible within 10 seconds to establish synchronisation between CPU 68332 PCB and Pneumatic Controller PCB. Cause: CPU 68332 PCB or Pneumatic Controller PCB defective. 02.00.004 si0_Err, Input data, chksum error, reset Data packets between CPU 68332 PCB and Pneumatic Controller PCB cannot be transferred in full. CPU 68332 PCB or Pneumatic Controller PCB defective. 02.00.005 si0_Err, Vector for NMI incorrect, reset RAM or SW error on CPU 68332 PCB 02.00.020 si0_Err, Si boot, case incorrect, reset RAM or SW error on CPU 68332 PCB or Pneumatic Controller PCB. 5664.500/800 Evita 4/Evita 2 dura 01.2002 Repair Instructions – 4 Fault Item Cause/Remedy 02.01.001 si1_ Err, Adjuster has incorrect pixel sum, X alarm, reset: Screen content (with Evita 2 dura also 7- segment displays) is read out and compared to request. Cause: Hardware or SW error on Graphics Controller PCB (Evita 4)/Front Panel PCB (Evita 2 dura) or CPU 68332 PCB or Pneumatic Controller PCB. If display plausible, then SW error; otherwise high probability of hardware error on Graphics Controller PCB (Evita 4) or Front Panel PCB (Evita 2 dura). Table for X: 1 Paw high adjuster selected 2 Paw high arrow selected 3 MV min adjuster selected 4 MV min arrow selected 5 O2 adjuster selected 6 Last adju

文档评论(0)

6358999 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档