PUBLIC UTILITY DISTRICT NO. 1 OF LEWIS COUNTY METERING SPECIFICATIONS General Metering Requirements Interpretation The District’s metering requirements shall not be interpreted to conflict with the regulations of the State of Washington or other regulatory bodies having jurisdiction. The District’s metering requirements may be more stringent. Meter Location and Accessibility The customer shall provide a location to connect metering equipment. The meter shall be free from obstruction, corrosive atmosphere, abnormal temperature, and convenient to the District’s distribution system. All meters, metering equipment, and enclosures shall be readily accessible by District personnel at all times for meter reading, maintenance, testing, installation or removal. All meter locations shall be subject to approval by the District. For overhead service installations, the meter and point of service attachment shall be located so as to provide proper safety clearance for the District’s service conductor and to allow for an unobstructed path from the District’s distribution transformer to the meter. For underground service installations the meter shall be located so as to minimize the overall length of the service from the District’s transformer to the meter. In the case where the service is installed in conduit, the service conduit run shall not contain any condulets or junction boxes ahead of the meter point, and the service conduit run shall not exceed a total of 180 degrees in bends. All conduit runs shall be subject to approval the District. Meter Sockets Meter sockets may be ring-type or ring-less and the District will supply the ring. The meter ring shall have a screw type locking mechanism. Snap rings are not acceptable. Meter socket height shall be a maximum of 7 ft. (6 ft. preferred), and a minimum of 5 ft. above finished grade or floor. The center of the meter socket is always the point of reference. When a meter socket enclosure is recessed in the b

您可能关注的文档

文档评论(0)

heti94575 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档