- 1、本文档共21页,可阅读全部内容。
- 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 5、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 6、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 7、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 8、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
ICPMSQudrupolecontroller演示文件修改版
Varian ICP-MSQuadrupole controller System overview The quadrupole controller generates the RF and DC control signals for the quadrupole. The ratio between the signals and their magnitude are variable. These signals determine which mass passes through the quadrupole and the resolution of the isotopic peaks. Access to the quadrupole controller It is a chassis mounted module located under the RF enclosure. To remove the unit, slide it out from the front of the instrument. The two controller output cables are fixed to high vacuum feedthroughs located in the bottom of vacuum chamber #3. The feedthroughs are screwed to each pair of quadrupole rods via metal tabs. These screws must be released before removing the mass analyser assembly. Quadrupole connection – vacuum feedthroughs Inside vacuum chamber#3 Under vacuum chamber#3 Gold plated pins proved a reliable connection into the rear mounted sockets of the quadrupole controller. Disconnect these to remove the unit. Power supply The controller operates on 230VAC supplied by the instrument mains input module. The mains input module is located in the lower right rear of the instrument. The mains cable is hard wired into the mains input module. What is inside? RF amplifier RF detector RF transformer Modulator PWB Control PWB Switching supplies Air cooling Two +24V fans provide cooling. One for the RF output transformer and the other for the switching supplies. Temperature has a significant impact on the controller operation. Fluctuating temperature will cause signal instability, most likely caused by drifting mass calibration. When troubleshooting always check that the fans are operational. Control PWB The control PWB is located in the front section of the unit. It is the interface to the instrument system control PWB. It generates HV DC signals for the drive signal. It generates the DC pole bias supply. It contains the resonation feedback and control circuitry. The HV section is not a
您可能关注的文档
- icepaknonconformal培训讲义.ppt
- ICNDCatalyst Switch Operations培训讲义.ppt
- ICNDSLTCP IP Internet Layer培训讲义.ppt
- Iconic Memory 培训讲义.ppt
- ICNDSLExploring the Functions of Networking培训讲义.ppt
- IBM WebSphere Portal at the Heart of an Exceptional Web ExperiencePortal打造酷炫入口新体验培训讲义.ppt
- ICT in Business Week 4培训讲义.ppt
- ICRP辐射防护体系的道德伦理基础培训讲义.ppt
- ICT in Business Week 培训讲义.ppt
- ICPMS课程引言培训讲义.ppt
- 初中数学与生物生态系统的跨学科教学设计研究教学研究课题报告.docx
- 小学语文教师教学画像构建与培训需求精准分析及课程设计研究教学研究课题报告.docx
- 信息技术与初中英语阅读教学融合的创新模式实践探索教学研究课题报告.docx
- 六、农业领域:农业生态补偿机制与区域生态环境改善研究教学研究课题报告.docx
- 基于传统文化的小学书法教育课程开发研究教学研究课题报告.docx
- 《图书馆均等化服务在公共图书馆服务均等化中的实践与启示》教学研究课题报告.docx
- 《微机电系统在精密制造领域的应用与发展》教学研究课题报告.docx
- 高中历史教学中历史意识培养的策略与实践教学研究课题报告.docx
- 5 《地下综合管廊防水防潮施工中的防水材料耐腐蚀性研究》教学研究课题报告.docx
- 2025至2030中国氯化苄行业销售状况及竞争格局分析报告.docx
文档评论(0)