1、确定用电负荷: (1)、插入式振动器 Kx = 0.3 Cosφ = 0.7 tgφ = 1.02 Pjs = 0.3×18 = 5.4 kW Qjs = Pjs× tgφ=5.4×1.02 = 5.508 kvar (2)、电焊机:(取暂载率J1=0.60 功率因素COSΨ=0.87) P电焊=S1*√J1 *COSΨ×10 =20×√0.60×0.87×4=28.9KW Kx = 0.65 Cosφ = 0.7 tgφ = 1.02 Pjs = 0.65×28.9 = 18.785kW Qjs = Pjs× tgφ=18.785×1.02 = 19.161 kvar (3)、木工圆锯机 Kx = 0.65 Cosφ = 0.7 tgφ = 1.02 Pjs = 0.65×1.5 = 0.975 kW Qjs = Pjs× tgφ=0.975×1.02 = 0.995 kvar (4)、钢筋弯曲机 Kx = 0.65 Cosφ = 0.7 tgφ = 1.02 Pjs = 0.65×5.5 = 3.575 kW Qjs = Pjs× tgφ=3.575×1.02 = 3.647 kvar (5)、钢筋套丝机 Kx = 0.65 Cosφ = 0.7 tgφ = 1.02 Pjs = 0.65×8 = 5.2 kW Qjs = Pjs× t