NDIRCO2DualChannelsGasSensor
NDIR SENSOR OGS-335
NDIR CO2 Dual Channels Gas Sensor
OGS-335
Revision Date: 2016/05/03 (Rev.02)
Introduction
The OGS-335 is a dual channels thermopile device having an output signal voltage directly
proportional to the incident infrared (IR) radiation power. Two infrared narrow band pass filters in front
of the sensor provide CO2 gas absorption signal and reference signal simultaneously.
Features
? Thermistor temperature reference included ? Fast response time
? High sensitivity ? Narrow band pass filters
Applications
? NDIR gas sensing ? Demand Control Ventilation (DCV)
? In door air quality monitoring ? Climate Control for Automobiles
? Obstructive Sleep Apnea monitoring ? Combustion Control for Furnace
? Industrial control ? Greenhouse
Specifications
Model OGS-335
Target Gas CO2
Filter CWLs 4.279 um (TP2)
3.91 um (TP1)
Window Size 1.5 mm in diameter
Spacing of Window 2.5 mm
Package Type TO-5
Parameter Typical Unit Conditions
Sensitivity 61 V/W 323K, w/o filter
o
TC of sensitivity 0.06 %/K 25 C
Tb:50℃, Ta:25℃ Transmittance of 4.279um filter and 3.91 um filter