ETL 1110-2-311 Fire Protection--Hydroelectric Power Plants.pdf

ETL 1110-2-311 Fire Protection--Hydroelectric Power Plants.pdf

  1. 1、本文档共11页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
ETL 1110-2-311 Fire Protection--Hydroelectric Power Plants

DEPARTMENT OF THE ARMY U.S. Army Corps of Engineers CECW-EE Washington, DC 20314-1000 ETL 1110-2-311 Technical Letter No. 1110-2-311 29 February 1988 Engineering and Design FIRE PROTECTION--HYDROELECTRIC POWER PLANTS Distribution Restriction Statement Approved for public release; distribution is unlimited. ,,, ,. ,. “ j’”” DEPARTMENT OF THE AF?MY ETL 1110-2-311 U.S. Army Corps of Enqineers CEEC-EE Washington, D.C. 20314+1000 Enqineer Technical Letter No. 1110-2-311 29 February 1988 Engineering and Desiqn FIRE PROTECTION --HYDROELECTRIC POWER PLANTS 1. Purpose. The purpose of this letter is to provide guidance for the upqradinq of fire prevention, fire detection, fire protection-and smoke control systems in existinq power plants. Means of emergency access and egress from the power plant, and the use of fire uesistinq materials when mdifyinq or installing new equipment or material in the power plant is also addressed. 2. Applicability. This letter applies to all HQUSACE/OCE elements and field operatinq activities having responsibility for Civil Works hydroelectric power plant projects. 3. References. a. b. c. d. e. f. ~. h. i. Jo EM 1110-2-4205 American Society of Heating, Refriueratinq and Air- Conditioninq Enqineers (ASHRAE) American Society for Testinq and Materials (ASTM) Institute of Electrical and Electronics Enqineers (IEEE) Industrial Risk Insurers (IRI) National Fire Protection Association (NFPA) National Electrical Code (NEC) National Electrical Manufacturers Association (NEMA) Occupational Safety and Health Administration (OSHA) Underwriters Laboratories Inc. (lJL) 4. Discussion. Typical hydroelectric powerhouse construction is of reinforced concrete and masonry type construction, therefore fire suppression for powerhouses has historically been limited to ‘~his ETL supersedes RTL 1110-2-245, 25 May 1979 ETL 1110-2-311 29 Feb 88 fire hoses and fiue extinguishers for protection of the structure. Special fire protection systems, such as carbon dioxide (C02) sy

文档评论(0)

l215322 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档