Abbott automatic biochemical analyzer interference analysis and prevention project
PAGE \* MERGEFORMAT 12
Abbott automatic biochemical analyzer interference analysis and prevention project
[Abstract] Objective: Abbott automatic biochemical analyzer (ABBOTT AEROSET) project testing process, after the previous test of a test project on the interference generated by the project and preventive measures. Methods: ABBOTT AEROSET biochemical analyzer on the test items one by one in sequence paired test, to determine a project before the test results after the interference of a project, by adding deionized water cleaning process and cleaning procedures were set alkali, acid washing procedures and other measures to prevent interference; for the project seriously disturbed, isolated from interference and tampering links between the project and will be placed in interference with the project until the project facilities interference detection, or interference with the project will be interfering with the project facilities were set up inside and outside the circle of the instrument response Cup. Results: LDL-C, CK, AST, HDL-C, CKMB, Cr, LDH, ALP and other projects on the back of an obvious interference test items to the deionized water cleaning process to prevent interference with the most obvious effect, eliminate the interference effective rate of 62.5%; while cleaning needle R1R2 two reagents, the interference was significantly reduced, relative deviation of some of the projects which substantially reduced. Conclusion: LDL-C, CK, AST, CKMB, LDH interference caused by setting the water cleaning program can be removed; caused by the interference of HDL-C by setting the basic alkaline cleaning program can be elimination; clean needles to eliminate interference with two reagents more effective than single agents needle cleaning better; cleaning program can not eliminate the interference of the project should change the test sequence.
[Keywords:] interference; prevention; automatic biochemical analyzer
Automatic biochemical analyzer with multi-s
您可能关注的文档
- A laptop bag with a brand of thinking caused.doc
- A letter addressed to young entrepreneurs.doc
- A large commercial mall marketing the Minister of War Record of the readme (b).doc
- A leading distributor to the letter Y.doc
- A letter addressed to chiefs of Dairy.doc
- A letter addressed to Mr. Ye's questioned.doc
- A labeling efficiency for the bio-chip research methods.doc
- A letter to the owners of SMEs - A company's management diagnosis report (draft).doc
- A letter to the sales staff.doc
- A letter to business owners.doc
- 食品饮料深度研究:破局与重构:中国软饮行业的发展新纪元.pdf
- AI智慧校园建设综合解决方案(45页PPT).pptx
- App浪潮下的数据安全和个人信息保护监管解决方案(33页PPT).pptx
- K3WISE智能制造解决方案(39页PPT).pptx
- 122工业互联网基本概念及关键技术(294页PPT).pptx
- PeopleSoft概述组织架构和人事管理(124页PPT).ppt
- 72智慧工业园区环境监测一体化解决方案(53页PPT).ppt
- AWS数据湖和大数据服务介绍(45页PPT).pptx
- 城市规建管一体化平台建设方案(43页PPT).pptx
- 96科技园区规划设计方案智慧科技园规划设计方案(43页PPT).pptx
文档评论(0)