High-frequency electric surgical knife in the accident caused injuries and preventive measures.docVIP
- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
High-frequency electric surgical knife in the accident caused injuries and preventive measures
PAGE \* MERGEFORMAT 11
High-frequency electric surgical knife in the accident caused injuries and preventive measures
[Key Words] high-frequency electric surgical knife accident prevention measures
High-frequency electric knife is a scalpel can be organized to replace mechanical cutting of electronic surgical instruments, which use blades at high current electrical discharge to the surface energy generated by rapid vaporization of tissue, freezing or cutting so as to achieve the purpose of medical procedures such as [1 ]. electrosurgical cutting speed, a good hemostatic effect, simple, safe and convenient in clinical use of high-frequency electric knife can greatly shorten the operation time, reduce blood loss and transfusion patients, thus reducing the cost of complications and surgical Therefore, high-frequency electric knife widely in clinical applications. but in use, such as failure to operate a point of order, likely to cause accidental injury, increasing the suffering of patients, causing conflicts and even lead to patient medical disputes, but also hurt the surgery staff itself. now in the high frequency electric knife during surgery due to accidental injuries and preventive measures are summarized below.
An electrode at the skin burn
Electrode burn 1.1 The main reasons for the role of electrode because of its own area, so that high-frequency current per unit area can be substantially dispersed into the body within the current organization of the human body is very small thermal effects, will not burn the skin. Electrode burns electrode was mainly due to surgery returned from the current density is too large, so that the electrodes were affixed to put parts produced a stream, the resulting burns [2]. This is caused by high frequency electric knife common causes of accidental injury [3-5 ]. But when the electrode wire breakage or distortion of the position at the rugged, if patients experience surgery or move operation can result in incorrec
您可能关注的文档
- High frequency ultrasound diagnosis of acute appendicitis.doc
- High frequency ultrasound diagnosis of acute appendicitis in 108 patients experience.doc
- High glucose inosine Danshen treatment centers combined energy mixture serous chorioretinopathy Clinical Observation.doc
- High glucose-induced bovine retinal microvascular pericytes FOXO1A increased expression of.doc
- High glucose on human peritoneal mesothelial cells gap junction protein.doc
- High glucose on the hepatic stellate cell proliferation and transforming growth factor 1 platelet-derived growth factor and procollagen typeexpression.doc
- High frequency ultrasound imaging in children with intussusception in the value of early diagnosis and treatment.doc
- High incidence of birth defects analysis of trace elements in geochemical environment.doc
- High incidence of cardiac esophageal and gastric cancer epidemic and its impact on endoscopic screening strength analysis of the Enlightenment.doc
- High homocysteine in elderly diabetic retinopathy and insulin resistance.doc
- High-frequency color Doppler ultrasound in breast masses Application.doc
- High-frequency electrical discharge of water-acupuncture athletes clinical study of lumbar disc herniation.doc
- High-frequency electric knife clean sheet of the application of two kinds of placement Comparison.doc
- High-frequency electric therapy efficacy in 231 cases of cervical erosion.doc
- High-fat diet-induced SR-A- Ⅱ gene knockout mice the formation and mechanism of obesity.doc
- High-frequency electric therapy Branchofiberoscope central airway stenosis care.doc
- High-frequency electrical discharge of water-acupuncture therapy in experimental osteoarthritis chondrocyte apoptosis.doc
- High-frequency color Doppler ultrasound diagnosis of superficial nerve sheath tumor of the value of.doc
- High-frequency jet ventilation for no pain fibers in the Effects of bronchoscopy.doc
- High-frequency color Doppler ultrasonography in the diagnosis of breast lumps.doc
最近下载
- 教师口语基础.pptx VIP
- 周杰伦所有歌词(14张专辑-包括床边的故事)呕心沥血已经整理完毕可打印.doc VIP
- 2025年秋期部编人教版四年级上册语文全册核心素养教案(教学反思无内容+二次备课版).pdf
- 箱式破碎机技术参数.docx VIP
- 贯入法检测砂浆计算表(自动计算2017).xls VIP
- 2025届河南资本集团投资公司校园招聘启动笔试上岸历年真考点题库附带答案详解.doc
- 【2025秋新版】【二升三年级语文】 必背古诗30首全文.pdf VIP
- 《教师职业道德与学前教育政策法规》课程教学大纲.docx
- 北师大版九年级数学上册课程纲要.doc VIP
- 初中生物新教材培训心得.pptx
文档评论(0)