- 1、本文档共8页,可阅读全部内容。
- 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
PENTRA-120Retic instrument performance evaluation
PAGE \* MERGEFORMAT 8
PENTRA-120Retic instrument performance evaluation
OF: Juan Lau Yi Xiao Hu FORCES
Keywords:] PENTRA-120Retic instrument performance PENTRA-120Retic ABX HORIBA instrument is the French company’s automatic five-classification and reticulocytes (Reticulocyte, RET analysis instrument, which also has a multi-parameter on the performance of RET analysis, to provide more useful for clinical reference. Instrument testing speed fast, when do RET testing 120 samples per hour, so RET may also be detected in 60 specimens per hour, the instrument can be tested during the automatic washing, instrument performance is superior than the traditional test that reticulocyte RET # RET%, and with a single parameter value, does not reflect the maturity of reticulocytes shortcomings, in recent years, automatic blood cell analyzer, flow cytometry analysis, automated analytical instruments for the reticulocyte count provides advanced detection instruments and more relevant parameters. the use of automatic flow blood cell analyzer reticulocyte, reticulocyte percentage obtained (RET%), absolute reticulocyte (RET #), low percentage reticulocyte fluorescence intensity ratio (LFR ), the fluorescence intensity of reticulocyte percentage (MFR), high fluorescence reticulocyte percentage rate (HFR) and a series of parameters (the presence of RNA according to the amount of red blood cells maturity will be divided into three). I Branch Last year bought a the model of instrument used for a year’s time, our performance of this instrument in particular its performance in the detection of RET were evaluated, test results will now be reported as follows.
1 Instruments and methods
1.1 The equipment produced by the French ABXHORIBA PENTRA-120Retic, the reagents used are imported and quality control. Huang tar blue dye, clean slide.
1.2 Methods
1.2.1 RET precision of quality control check, the patient (high value, low value of the healthy human whole blood on a co
您可能关注的文档
- Pediatric Clinical C. meningosepticum septicemia of Bacillus.doc
- Pediatric Clinical Factors Massage.doc
- Pediatric clinical pharmacist in the role of therapeutic drug monitoring.doc
- Pediatric Clinical Pharmacology yet to be developed.doc
- Pediatric Clinical Pharmacist Training.doc
- Pediatric clinical significance of penicillin sensitivity again.doc
- Pediatric clinical practice teaching problems and reform measures.doc
- Pediatric concealed penis selection and evaluation of surgical methods.doc
- Pediatric Constipation Therapy Clinical study of TCM.doc
- Pediatric cardiopulmonary bypass on postoperative inflammatory response.doc
文档评论(0)