中性点非有效接地配电网故障选线新原理_.pdfVIP

中性点非有效接地配电网故障选线新原理_.pdf

  1. 1、本文档共6页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  5. 5、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  6. 6、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  7. 7、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  8. 8、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
中性点非有效接地配电网故障选线新原理_

Journal of Southeast University(English Edition) June 2000 Vol. 16 No. 1 ISSN 1003) 985 New Principle for Grounding Fault Feeder Detection in MV Distributions wit h Neutral Ineffectively Eart hed X Zeng Xiangjun Yin Xianggen Chen Deshu Zhang Zhe ( Department of Electrical Power Engineering, Huazhong University of Science and Technology, Wuhan 4300 4) Abstract: A new principle for grounding fault feeder detection based on negative sequence current variation and energy dissipated in the fault point is presented. It has high precision in both isolated systems and resonance earthed systems, even in ful-l compensated systems. And it can be installed at the local control unit of feeder in distribution automation systems, such as field terminal unit ( FTU) . This principle is verified by EMTP simulator and experimentation. Key words: protective relaying, fault detection, distribution networks Most distribution networks are isolated systems or resonant earthed neutral systems in China. These distributions with neutral ineffectively grounding can achieve significant and economical improvements in safety and power supply quality. Unfortunately, grounding fault feeder is difficult to be detected in these distributions[ 1- 3] . In isolated systems, the zero sequence current magnitude of grounding fault feeder is the sum of other sound feeds. , and the zero sequence current direction of grounding fault feeder is opposite to sound feeders. . So the grounding fault feeder can be detected by comparing fundamental zero sequence current. s amplitudes or phases in the isolated systems. However, in resonant earthed systems, grounding fault current is very small. The direction of fundamental zero sequence current is disturbed by the compensation curren

文档评论(0)

ranfand + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档