Enzymatic Determination of Diglyceride Using an Iridium Nano-Particle Based Single Use, Disposable Biosensor
Sensors 2010, 10, 5758-5773; doi:10.3390/s100605758
OPEN ACCESS
sensors
ISSN 1424-8220
/journal/sensors
Article
Enzymatic Determination of Diglyceride Using an Iridium
Nano-Particle Based Single Use, Disposable Biosensor
Shu-Yi Hsu 1, Brandon Bartling 2, Christina Wang 3, Fuh-Sheng Shieu 1 and Chung-Chiun Liu 2,*
1
Department of Materials Science and Engineering, National Chung Hsing University, Taichung
40227, Taiwan; E-Mails: g9766119@.tw (S.-Y.H.);
fsshieu@.tw (F.S.S.)
2
Department of Chemical Engineering and Electronics Design Center, Case Western Reserve
University, 10900 Euclid Avenue, Cleveland, OH 44106, USA; E-Mail: bxb79@
3
Department of Biological Sciences, College of Arts and Sciences, Cornell University, 147 Goldwin
Smith Hall, Ithaca, NY 14853-3201, USA; E-Mail: cpw39@
* Author to whom correspondence should be addressed; E-Mail: cxl9@;
Tel.: +1-216-368-2935; Fax: +1-216-368-8738.
Received: 26 April 2010; in revised form: 15 May 2010 / Accepted: 28 May 2010 /
Published: 8 June 2010
Abstract: A single use, disposable iridium-nano particle contained biosensor had been
developed for the determination of diglyceride (DG). In this study hydrogen peroxide, formed
through the enzymatic breakdown of DG via lipase, glycerol kinase and glycerol 3-phosphate
oxidase, was electrochemically oxidized at an applied potential of +0.5 V versus the
Ag/AgCl reference electrode. The oxidation current was then used to quantify the
diglyceride concentration. Optimum enzyme concentrations and the surfactant loading used
were established for successful sensor response. Good linear performance was observed
over a DG concentration range of 0 to 25 μM in phosphate buffer and bovine serum media.
Keywords: diglyceride; disposable biosensor; enzyme
1. Introduction
Diglyceride (diacylglycerol, DG) is a simple lipid consisting of a glycerol molecule linked through
ester bonds to two fatty acids. Its small
您可能关注的文档
- Endometrial Glandular Dysplasia (EmGD) morphologically and biologically distinctive putative precursor lesions of Type II endometrial cancers.doc
- Endoscopically assisted procedure for removal of a foreign body from the maxillary sinus and contemporary endodontic surgical treatment of the tooth.doc
- Endocrine disruptor screening regulatory perspectives and needs.doc
- Endothelin 1 levels in relation to clinical presentation and outcome of Henoch Schonlein purpura.doc
- Endothelin antagonists new bullets against lung injury.doc
- Endotoxin neutralization and anti-inflammatory effects of tobramycin and ceftazidime in porcine endotoxin shock.doc
- Endotoxemia related to cardiopulmonary bypass is associated with increased risk of infection after cardiac surgery a prospective observational study.doc
- Endotracheal tubes and imposed work of breathing what should we do about it, if anything.doc
- Endotoxemia-induced inflammation and the effect on the human brain.doc
- Energetics of nanoparticle oxides interplay between surface energy and polymorphism?.doc
- Enzymaktivit?ten im blutserum von m?usen unter dem einfluss der selektion auf belastbarkeit.doc
- Enzymatic Activity Enhancement of Non-Covalent Modified Superoxide Dismutase and Molecular Docking Analysis.doc
- Environmentally Sensitive Fluorescent Sensors Based on Synthetic Peptides.doc
- Environmental Strategies for Electrical and Electronic Equipment Supply Chains Which to Choose.doc
- Envisat Ocean Altimetry Performance Assessment and Cross-calibration.doc
- Enzymatic Reduction of 9-Methoxytariacuripyrone by Saccharomyces cerevisiae and Its Antimycobacterial Activity.doc
- Enzymatic Synthesis and Crosslinking of Novel High Molecular Weight Polyepoxyricinoleate.doc
- Enzymatic Kinetic Resolution of tert-Butyl 2-(1-Hydroxyethyl)phenylcarbamate, A Key Intermediate to Chiral Organoselenanes and Organotelluranes.doc
- Enzyme Immobilization Strategies and Electropolymerization Conditions to Control Sensitivity and Selectivity Parameters of a Polymer-Enzyme Composite Glucose Biosensor.doc
- Enzymatic digestion of articular cartilage results in viscoelasticity changes that are consistent with polymer dynamics mechanisms.doc
文档评论(0)