- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
剪力墙基础请求(国外英文资料)
剪力墙基本要求(国外英文资料)
The basic requirements of the shear wall design (excerpt from a chapter of the high gauge shear wall)
7.1.9 seismic design, the bottom of the shear wall structure strengthening highly desirable wall limb of the 1/8 of the total height and the bottom two layers of the larger value of the two, when the shear wall height more than 150 m, the strengthening part at the bottom of the highly desirable wall limb 1/10 of the total height; The height of the strengthening part of the shearing force wall shall be in accordance with the provisions of article 10.2.4 of this regulation.
7.2.15 one, the seismic design of the secondary shear wall at the bottom of the strengthen part and a layer of wall limb end should according to the requirements of this code article 7.2.16 binding edge artifacts; One, the other parts of the seismic design of the secondary shear wall and three or four seismic design and seismic design of shear wall wall limbs end shall be according to the requirements of this code article 7.2.17 set structure edge artifacts.
The vertical and horizontal bar of the high building shear wall should not be used in single-line reinforcement. When the thickness of the shear wall is not greater than 400mm, a double rib is used. When bw is greater than 400mm, but no more than 700mm, use three lines of reinforcement; When bw is larger than 700mm, use four lines of reinforcement. The force bar can be evenly distributed into several rows. Each row of distribution of the pull between rebar spacing should not be greater than 600 mm, should not be less than 6 mm in diameter, strengthen the parts in the bottom, outside edge constraint component of joint spacing should be proper encryption.
7.2.16
1 the length of the edge constraint component along the direction of wall limb lc and stirrup stirrup characteristic value should meet the requirements of the table 7.2.16 lambda v and a, level 2 seismic design stirrups should not be less than 8 mm diameter, stirrup spaci
文档评论(0)