安全装置常见故障和处理方法(国外英文资料)
安全装置常见故障和处理方法
Displacement sensor, weighing sensor, light screen sensor, flat layer sensor, velocity coder, etc.
The third part
Common failures and handling of safety devices
one
Stop circuit failure
The phenomenon of
Stop relay
(
Voltage relay
)
Dont suck.
why
In the emergency power line of the elevator, the coils of the stop relay are generally closed to the following safety switches
In series, such as bottom-hole emergency stop switch, speed limiter switch, safety window switch, car top urgent stop switch, sedan chair
Stop switch, safety clamp switch,
Phase-sequence relay contact
The towing motor relay contact, owing to magnetic relay
Contact,
Steel band switch, etc.,
Any of these switches will break off the relay coil
Electrical discharge, which makes the control circuit of the elevator fail to start.
Processing method
1.
Check for the cause of the failure of the safety switch and repair it.
2.
Maintain safety switch on a regular basis
As a reliable. In operation, it is absolutely forbidden to use wire short switch contact, which causes the elevator to run.
2
Limit switches do not fall
The phenomenon of
The elevator is at the end of the pole and the car is not able to touch the limit switch.
why
The tension between the car is too large or the pressure is less than the limit
On the switch ratchet, the switch cant pull down.
Processing method
Adjust the gap between the car and the wheel, and make it suitable for the production of wire rope
Theres enough tension to transfer to the limit switch.
Adjust the required
1.
When the elevator is slower than the end point,
Limit switch should be sensitive.
2.
Limit switch
When the action is done, the distance between the lower and upper end of the car is the distance from the upper and lower part of the car
50
~
200 mm
It is.
3
Door interlock switch failed
The phenomenon of
The door lock relay is closed and closed.
why
Because the lock relay coil is connected to the door lock of the various floors, the s