The Point堵煤开关英文说明书
DREXELBROOK
?
A Leader In Level Measurement Solutions
ThePoint? RFSeries
Point Level Switch for Plugged Chute Detection
Eliminate Costly Plugged Chutes
with Drexelbrook Sensors!
Downtime is expensive and so is the
clean up of process spills.
Reliable detection of plugged chutes will keep your
plant running smoothly and virtually eliminate spills
that occur because of plugged conditions.
Drexelbrook’s Flush-Mounted Sensors
reliably detect presence or absence of material
?owing through chutes. If process material stops
?owing due to a plugged condition, the system will
alarm, allowing further action to occur (alerting an
operator, shutting down a conveyor belt, etc.). This
permits the operator to prevent a problem before
it happens.
Intelligent Electronics Save Time and
Money
? Automaticallyrecognizesandignorescoatingsto
preventfalsealarms.
Rugged sensor design
? Universal power supply automatically detects
adjuststoinputpowersource
makes these systems ideal for coal (pulverizer and
transfer chutes), wood chips, ores, powders, etc.
Since they are ?ush mounted through a chute wall,
nothing protrudes into the chute to interfere with or
to obstruct material ?ow.
? Standard High Sensitivity Electronics, Field
Selectable
Application
? Detects the presence of plugged material in
chutes
Dust coating and/or wall build up will not
affect the measurement.
Economical Without Sacri?ce
? Retainssuperiorperformance.
? Less maintenance than other technologies; no
movingpartstohanguporwearout.
Drexelbrooks Cote-Shield circuitry “Sees” through
any coating condition and eliminates false plugged
chute signals.
Output
? DPDTrelaydrycontactsat5A,120VAC.
Curved and ?at sensors are available.
Chutes vary in size and shape. We have a sensor
design to ?t your chute.
Remote Electronics
? Unlike many technologies, electronics can be
remotemountedtoaconvenientorsafelocation
The Point?
Speci?cations
Ingress Protection:
IP66 NEMA 4X
Technology:
RF Admittance.
App