北京机场航站楼空调负荷特性分析(国外英文资料)
北京机场航站楼空调负荷特性分析(国外英文资料)
Analysis of air conditioning load characteristics of Beijing airport terminal
The Beijing institute of design and design, the summer order, huang jiyi
Summary: in this paper to airport terminal, the unique has streamlined the whole roof, huge overhangs, building their own shelter, height fluctuation significantly change the glass curtain wall, such as large area within the area of the room construction as the research object. Using the DeST construction simulation software, through all-year hourly air conditioning load simulation analysis and calculation, the analysis of the effect of the building block of palisade structure load, glass curtain wall thermal performance and annual air conditioning load impact factor, and air conditioning scheme selection for building palisade structure optimization to provide more comprehensive and accurate design basis.
Keywords: terminal, building simulation software, cold and heat load
Building features of the terminal building
From the layout of the terminal and 2-4, the exterior and interior space structure are more complex. From the perspective of architectural thermal analysis, the terminal has the following features: a streamlined, whole roof, huge overhangs; The building itself is obscured by the obvious; A glass curtain wall of highly fluctuating elevation; The vertical space that connects vertically; Large area rooms and large skylights with regular layout.
Figure 1. Profile location diagram
Figure 3. E-e profile
Figure 2. N - N profile
Figure 4. L-l section (partial)
The above characteristics of the terminal, one of the biggest difficulties for the design of hvac is the inability to use the traditional method of load calculation to calculate the air conditioning load. For two reasons: first, the traditional load calculation methods are difficult to calculate the external surface of the enclosure structure after the shade shadow area, and the terminal of the buildings that overhangs a very large are