- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
消防水池与消防水泵房(国外英文资料)
消防水池与消防水泵房(国外英文资料)A fire hydrant and fire pump roomIn accordance with one of the following rules, the fire tank shall be set up:When production and living water use reaches maximum, municipal water pipes, water pipes or natural water sources are not sufficient for the domestic and outdoor fire use.2 municipal water supply pipes are branch or only 1 feed pipe, and the total amount of water and water in indoor and outdoor fire is greater than 25L/s.The fire pool shall comply with the following provisions:1 when the outdoor water supply pipe network can ensure the outdoor fire water consumption, the effective capacity of fire pool should meet the requirements of indoor fire control water fire time. When the outdoor water supply pipe network can not guarantee outdoor fire water consumption, the effective capacity of fire pool should meet the indoor fire water and fire time outdoor fire water consumption is less than the sum of the parts.The capacity of the fire tank can be reduced by the amount of water added in the duration of the fire when the water supply is adequate and the water supply is guaranteed in the event of fire.The amount of water shall be determined by calculation and the design velocity of the supplementary water pipe shall not be greater than 2.5 m/s.The amount of water in the fire pool shall not exceed 48h; No more than 96h for water shortages or independent oil storage areas;A fire tank with capacity of more than 500m3 shall be divided into two independent fire pools.The fire tank for the fire truck shall set up the water inlet or the water well, and the suction height should not be greater than 6.0 m. The distance between the water intake or the well and the building (except the pump room) shall not be less than 15m; The distance between a, b and c liquid tanks should not be less than 40m.The distance from the liquefied petroleum gas storage tank should not be less than 60m, which can be reduced to 40m if protective measures are taken to prevent radi
文档评论(0)