空调水系统设计和可能出现的问题分析(国外英语资料).doc

空调水系统设计和可能出现的问题分析(国外英语资料).doc

  1. 1、本文档共31页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
空调水系统设计和可能出现的问题分析(国外英语资料)

空调水系统设计和可能出现的问题分析 Air conditioning room size and net depth The area of air conditioning occupies the proportion of the building area Building type Percentage (%) Building type Percentage (%) Tourist hotels, restaurants 70 ~ 80 The hospital 15 to 35 Office building and exhibition center 65 ~ 80 The department store 50 ~ 65 The theatre, the cinema, the club 75 ~ 85 Estimate of the area of air conditioning room building area Air-conditioned building area (m2) airway Fan coil with new wind (unit) (m2) Double duct (m2) The average estimate (m2) 1000 75 (7.5) - 70 (7.0) 70 (7.0) 3000 190 (6.3) 120 (4.0) 200 (6.7) 200 (6.6) 5000 310 (6.2) 200 (4.0) 300 (6.0) 290 (5.8) 10000 550 (5.5) 350 (3.5) 500 (5.0) 450 (4.5) 15000 750 (5.0) 550 (3.7) 600 (4.0) 600 (4.0) 20000 960 (4.8) 730 (3.7) 700 (3.5) 770 (3.8) 25000 1200 (4.8) 850 (3.4) 900 (3.2) 920 (3.7) 30000 1400 (4.7) 1000 (3.0) 1000 (3.0) 1090 (3.6) 1.3 layer Placement principle: High-rise buildings within 20 floors: the upper or lower layers should be set High-rise buildings within 30 storeys: two layers of equipment should be on top and bottom Above 30 floors above tall buildings: appropriate in the upper, middle and lower layers The principle of piping layout in the equipment layer: Leave the ground h less than or equal to 2.0 m to decorate air conditioning equipment, water pump and so on H = 2.5 ~ 3.0 m for cold, hot water piping H = 3.6 ~ 4.6 m for air conditioning and ventilation H 4.6 m for wiring cables The equipment is highly sketchy Building area (m2) Device layer (m) Building area (m2) Device layer (m) 1000 4.0 15000 5.5 3000 4.5 20000 6.0 5000 4.5 25000 6.0 10000 5.0 30000 6.5 Second, cold load calculation An estimate of the cold load of buildings building Cooling load W/m2 Sojourners m2 / person Lighting W/m2 Delivery l/sm2 Sensible cooling load The total cooling load The office In the central area 65 95 10 60 5 The surrounding 110 160 10 60 6 Personal office 160 240 15 60 8 The meeting room 185 270 3 60 9 The

您可能关注的文档

文档评论(0)

jgx3536 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档