低压供液管结霜的原因和检修(国外英语资料) Reasons for frosting of low pressure supply pipe of air conditioner and examples of maintenance The low pressure supply pipe in the air conditioner is the connecting pipe from the capillary outlet to the inlet of the evaporator. There are three reasons for frosting of low pressure liquid supply pipe: 1, normal frost. When the air conditioner starts to run, because the condensing temperature and the condensing pressure are lower, the capillary supply volume is lower than the normal value, so that the evaporation pressure decreases, so the frosting of the low pressure liquid supply pipe occurs. But this frost to melt is only a short process, usually in the compressor after running began to frost, 5 minutes after the entire process of frost melting all over, the air conditioner into normal operation. 2, fluoride deficiency. When the air conditioner is short of refrigerant, the frosting of the low pressure liquid supply pipe is a typical fault phenomenon. This phenomenon is manifested in the operation from the air conditioner, low pressure liquid pipe began to frost, and when the compressor does not disappear after running for more than 10 minutes. The cause of fluoride deficiency may be normal for an air conditioner for years, as long as the refrigerant is added. For only two or three years or just installed shortly after the lack of fluoride phenomenon, it is caused by leakage of refrigeration systems. 3 、 partial blockage of refrigeration system. The plugging point is usually found at the filter outlet or capillary inlet. The throttling effect is caused by the local blockage in the system, so that the pressure after throttling is lower than the normal value of the air conditioner, and the frosting of the liquid supply pipe is caused. The lack of fluoride and blockage will make the liquid supply pipe frosting, return air pressure, running current, condenser exhaust temperature lower than normal value, the two fault phenomenon is very similar, in

您可能关注的文档

文档评论(0)

jgx3536 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档