地下室底板抗浮措施(国外英语资料).doc

  1. 1、本文档共6页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
地下室底板抗浮措施(国外英语资料)

地下室底板抗浮措施(国外英语资料) Anti floating measures for basement floor An outdoor pool fire, 4 meters deep, underground water level 0.5m, in order to solve the problem of anti floating, the pool covering soil, pool or low uplift pile, but the pool of top soil is too thick, how and what better can solve the anti floating Anyway, is to think of ways to increase the weight of Bai, wall panels are thicker ~! If you dont, the flowers will only pile up It is the most direct and effective method to use the top covering of soil to solve the problem of anti floating and to solve the problem of pond water icing In fact, to increase the floor weight is the best choice ~! When calculating the floor plate, increasing the deadweight of the floor does not increase the load on the floor, as buoyancy is offset by ~ Bottom board pick 1~2m, general anti floating can be solved. No more sand on the bottom. In the concrete cold talk, check it out! Mention a standard CECS86-96 These two specifications can be referred to The anti floating design of rectangular pool and clear pond can be carried out, which is more typical The pond is usually covered with roof and covered with soil No cap pond generally use self weight, anti floating, self weight plus counterweight, uplift pile anti float, set one-way valve The main control parameter is the coefficient of safety against floating (specification can be found, generally 1.05) Anti floating calculation: 1. calculated the pool of water buoyancy F, that is, using the buoyancy formula in physics to calculate, groundwater levels generally take outdoor design, ground below 0.5m; 2. calculate the dead weight of tank G; 3., control anti floating: (0.9) G-1.2F should be no less than 0; if Shanghai area, the weight of G sub factor 1; if the nonlocal G coefficient of 0.9. 4., general measures: 1) increase the length of the outer panel, and the contribution of the overlying soil to the G 2) hit the uplift pile First calculate the empty pool (the worst case) than the

文档评论(0)

jgx3536 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档