可修复伺服驱动器常见故障(国外英文资料) Can repair the servo drive common faults: no display, lack of phase, over current, overvoltage, undervoltage, overheating, overload, grounding, parameter errors, has shown no output, module damage, error, etc.; The panasonic servo-throwing code has: ERR 11; ERR 12; ERR 13; ERR 14; ERR 15; ERR 16; ERR 18; ERR 20; ERR, 21; ERR 22; ERR, 23; ERR 24; ERR, 25; ERR 26; ERR, 27; ERR 29; ERR 35; ERR 36; ERR 37; ERR, 38; ERR, 40; ERR 41; ERR, 42; ERR 44; ERR 45; ERR 47; ERR, 97. Protection function Call the police code The cause of the fault should be dealt with Control the power Under voltage 11 The voltage is lower than the specified amount on the power inverter. 1) the ac power voltage is too low. Instantaneous loss of electricity. 2) the power capacity is too small. The voltage drop is caused by an instantaneous shock current. 3) the drive (internal circuit) is defective. Measure the voltage between L1C, L2C and r and t. 1) increase the power supply voltage. Replace the power supply. 2) increase power capacity. 3) please switch to a new drive. Overvoltage 12 The power voltage is higher than the allowable input voltage. The voltage over P and N on the inverter exceeds the fixed value. The power voltage is too high. There is a capacitive load or a UPS (uninterruptible power supply) Line voltage goes up. 1) no regenerative discharge resistance. 2) the regenerative discharge resistance of the outside is not matched and cannot be absorbed Raw energy. 3) the drive (internal circuit) is defective. Measure the phase voltage between L1, L2 and L3. Equipped with the right voltage. Exclude the capacity load. 1) use a meter to measure the resistance of P and B on the drive. If the reading is infinity, the resistance is not actually connected. Please change a. 2) switch to an external power that meets the specified value of a block and power Resistance. 3) please switch to a new drive. The main power supply Under voltage 13 Parameter Pr65 (voltage alarm is trigger

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档